Basic operation steps for different modes
BASIC OPERATION 73
4.3.3 Basic operation steps for JOG mode (00-16(P.79)=0 or 1)
Step
Description
1
•Switch operation mode to JOG mode and indicator in
PU
will light up, the display shows
.
Note: 1. For detailed operating procedures for the monitor mode, please refer to section 4.2.
2
•Press
FWD
or
REV
to run the motor. At this point, indicator in
FWD
or
REV
will flash, indicating that
the motor is running.
• Release
FWD
or
REV
to decelerate the motor until it comes to a full stop. Indicator in
FWD
or
REV
will not turn off until the inverter stops the output.
Note: 1. For detailed operating procedures for monitor mode, please refer to section 4.2.3.
2. In JOG mode, target frequency is the value of 01-13(P.15), and the acceleration / deceleration time is
the value of 01-14(P.16). Please refer to 5.2.7 JOG run.
4.3.4 Basic operation steps for communication mode (00-16(P.79)=3)
In communication mode, user can set parameters and run/stop or reset inverters by communication. Please
refer to
Communication function related parameters
for details.
4.3.5 Basic operation steps for combined mode 1 (00-16(P.79)=4)
Step
Description
1
•In Combined Mode 1, indicator in
PU
will flash.
Note: 1. For detailed operation procedures for monitor mode, please refer to section 4.2.
2
•Enter frequency setting mode and write target frequency into memory.
Note: For setting details, please refer to section 4.2.4.
3
•Set target frequency by PU301 keypad and start the inverter by digital input terminals.
• At this point, indicator in
FWD
or
REV
will flash, indicating that the motor is running.
Note: For detailed operation procedures for monitor mode, please refer to section 4.2.3.
4
•When digital input terminals output stop signals, motor will decelerate until it comes to a full stop.
• Indicator in
FWD
or
REV
will not turn off until the inverter stops outputting.
4.3.6 Basic operation steps for combined mode 2 (00-16(P.79)=5)
Step
Description
1
• In Combined Mode 2, indicator in
PU
will flash.
Note: 1. For detailed operation procedures for monitor mode, please refer to section 4.2.
2
• The target frequency is set by external terminal (the default priority is from high to low)
• If the program operation mode is selected, refer to section 5.4.1 Digital Input Function Option and section
5.5.2 Program Operation Mode.
• If target frequency is set by multi-speed, refer to section 5.5.1 Multi-speed 16.
• If target frequency is set by A2/B2 terminal input signal setting of PG card, refer to section 5.10.4 PG2
Parameter.
• If target frequency is set by PWM pulse input, refer to section 5.4.1 Digital Input Function Selection.
•If target frequency is set by 2-5 terminal input signal, refer to section 5.3.5 2-5 Input Selection and Processing.
•If target frequency is set by 4-5 terminal input signal, refer to section 5.3.6 4-5 Input Selection and Processing.
•If target frequency is set by 3-5 terminal input signal, refer to section 5.3.7 4-5 Input Selection and Processing.
•If target frequency is set by HDI terminal high-speed pulse input, refer to section 5.3.8 HDI Input Selection
and Processing.