Electric specification
INVERTER INTRODUCTION20
Frame
E
F
G
Model SA3-023-
【】
45K/
55KF
55K/
75KF
75K/
90KF
90K/
110KF
110K/
132KF
In
ve
rt
er O
u
tp
u
t
HD
Rated output capacity
(kVA)
65
82
110
132
165
Rated output current (A)
170
215
288
346
432
Applicable motor
capacity (HP)
60
75
100
120
145
Applicable motor
capacity (kW)
45
55
75
90
110
Overload current rating
150% 60 seconds, 200% 3seconds (inverse-time characteristics)
Carrier frequency (kHz)
1~9kHz
ND
Rated output capacity
(kVA)
82
110
132
165
193
Rated output current (A)
215
288
346
432
506
Applicable motor
capacity (HP)
75
100
120
145
175
Applicable motor
capacity (kW)
55
75
90
110
132
Overload current rating
120% 60seconds (inverse-time characteristics)
Carrier frequency (kHz)
1~9kHz
Maximum output voltage
3 phase 200-240V
Po
w
er S
u
p
p
ly
Rated input AC voltage/
frequency
3 phase 200-240V 50Hz / 60Hz
Permissible AC voltage
fluctuation
3 phase 170-264V 50Hz / 60Hz
Permissible frequency
fluctuation
±5%
Power supply capacity (kVA)
79
100
110
132
165
Rated input current
(A)
*Note 1
HD
180
250
300
380
450
ND
250
300
380
450
520
Cooling method
Fan cooling
Inverter weight (kg)
42.7
42.7
56.5
89.2
90.2
Note 1: The value indicates the current at rated output. The rated input current value is not only affected by power
transformer, input side reactor, wiring condition, but also fluctuates with the impedance of the power supply side.
Note: The test conditions for rated output current, rated output capacity, inverter power consumption are: carrier
frequency 00-11(P.72) set default; inverter output voltage 440V; output frequency 60Hz, ambient temperature
40℃.