System parameter group 00
PARAMETER DESCRIPTION 89
5.1.4 Monitoring function
The item displayed on the keypad can be selected.
Parameter
Name
Default
Setting Range
Content
00-06
P.110
Keypad monitoring
selection
1
X0
X0: When inverter starts, keypad enters monitor mode
automatically, screen displays output frequency. (Note 1)
X1
X1: When inverter starts, screen displays target frequency.
X2
When inverter starts, keypad enters monitor mode
automatically, screen displays current pressure and feedback
pressure of the constant pressure system in percentage.
(Note 2)
X5
When inverter starts, keypad enters monitor mode
automatically, screen displays current pressure and feedback
pressure of the constant pressure system. (Note 3)
0X
Boot screen monitors output frequency
1X
Boot screen is in target frequency setting mode
2X
Boot screen monitors output current
3X
Boot screen monitors output voltage
00-07
P.161
Multi-function display
0
0
Output AC voltage (V)
1
Voltage between (+/P) and (-/N) terminals. (V)
2
Inverter temperature rising accumulation rate (%)
3
Target pressure of the constant pressure system (Unit set
by 08-44(P.252))
4
Feedback pressure of the constant pressure system (Unit
set by 08-44(P.252))
5
Running frequency (Hz)
6
Electronic thermal accumulation rate (%)
7
Signal value (V) of 2-5 input terminals.
8
Signal value (mA) of 4-5 input terminals (mA/V).
9
Output power (kW).
10
PG card feedback rotation speed. (Hz)
11
Forward reverse rotation signal. 1: forward rotation 2:
reverse rotation 0: stop.
12
NTC temperature (℃)
13
Motor electronic thermal accumulation rate (%)
14
Reserved.
15
Input frequency of terminal HDI. (kHz)
16
Real-time roll diameter. (mm)
17
Real-time line speed. (m/min)
18
Output torque of inverter (%)(Valid only when 00-21 (P.
300) or 00-22 (P. 370) is set to 3 ~ 6 )
19
Digital terminal input state
20
Digital terminal output state
21
Actual working carrier frequency
22
Signal value (mA) of 3-5 input terminals. (mA/V)
23
Synchronous motor rotor pole position(Show motor rotor
magnetic pole position from encoder feedback, valid when
00-21 (P. 300) = 5)