Section 3: Interface Specifications
TG3 Series Service Manual
Page 3-11
3.5 LOCAL AREA NETWORK (LAN) ETHERNET (Cont’d)
3.5.1 Basic Specifications (Cont’d)
Communication setup
The following communication settings are available in the Interface Mode of the
printer.
Item
Setting range
Protocol
STATUS3
STATUS4 (Cyclic response mode)
STATUS4 (ENQ response mode)
STATUS5
IP address
0.0.0.0 ~ 255.255.255.255
Subnet mask
0.0.0.0 ~ 255.255.255.255
Gateway address
0.0.0.0 ~ 255.255.255.255
* IP address, Subnet mask, Gateway address are settable through [Admin Man-
ager], the utility of attached CD-ROM. In this case, each setting value is saved to
the interface board directly. Go to [Configuration] of the Interface Mode to enable
the setup by either the Interface Mode or [Admin Manager].
Maximum receive
buffer capacity
2.95MB
Buffer near full
Buffer near full
0MB
2.95MB
Remaining 0.95MB
Remaining 1.95MB
occurred
released