Section 7: Replacement Procedures
TG3 Series Service Manual
Page 7-37
7.23 REPLACING CUTTER UNIT
Before replacement, check the
Cut counter
as explained in
Section 6.4 Counter Display Mode
.
1.
With the power supply is off, lift up the
main cover
.
2.
Unscrew the
shaft
(1) that holds the
cutter unit
(2) in place, removed the
shaft
(1) and set aside. Care-
fully lift and pull out the
cutter unit
(2).
3.
Disconnect the
wiring harnesses
from the defective
cutter unit
(2), replace the
cutter unit
(2) and
reverse the above procedures for reassembly.
Note:
Insert the
wiring harnesses
firmly and arrange the
wiring harnesses
to ensure that they are not
pinched during installation.
4.
After replacement of
cutter unit
, perform the following adjustment procedures.
Refer to the Adjustment Procedures section of this manual for the procedures listed below.
1. Cut counter clear function
Refer to
Section 6.3 Counter Clear Mode
.
2. Adjustment of Cutter sensors
Refer to
Section 6.10 Adjusting Cutter Sensors
.
3. Adjustment of Cutter timing belt tension
Refer to
Section 6.20 Adjusting Cutter Motor Timing Belt Tension
.