Section 6: Checks and Adjustment Procedures
Page 6-20
TG3 Series Service Manual
6.9 ADJUSTING AND CHECKING SENSORS (Cont’d)
6.9.4 Edge Sensor Sensitivity Adjustment
This sensor adjustment regulates penetrating ability for media referencing. The edge sensor is located next to
I-Mark sensor.
To adjust the Edge sensor level with the Operator Panel
Note:
This calibration is only for fine tuning. There may isn’t any significant value changes during adjustment,
depends on the media used. In this case, adjust the sensor level by the
VR
potentiometer on the
Main PCB
(CONT)
.
1.
Enter to SENSOR LEVEL setting screen and press the
FEED
button repeat-
edly until PAPER SENSOR EDGE is
selected.
2.
Disengage the
Head lock Lever
and the
Lid Latch
to allow media loading.
Physically position the media, with the R-corner tag rests over the
Edge
sensor.
Note:
• To stabilize the sensor level, make sure the print head assembly is locked and the media is threaded
correctly.
3.
Check the sensor response via the LCD screen.
The LCD screen will display
[1]
if tag is set on the edge sensor and display
[0]
if no tag is set.
4.
Repeat
step 2
with the tag taken out and check the LCD screen.
If the LCD screen does not response correctly, proceed to next step to adjust the sensor level.
5.
Press the
/ arrow
buttons to adjust the sensor level and press the
FEED
button. Enter the value within
the range of 0 to 63. The initial value is 31.
I-Mark/ Edge sensor
Summary of Contents for TG308
Page 1: ...Service Manual For printer model TG3 Series www satoamerica com PN 9001226 A...
Page 6: ...Table of Contents Page iv TG3 Series Service Manual This page is intentionally left blank...
Page 7: ...Section 1 Introduction TG3 Series Service Manual Page 1 1 INTRODUCTION...
Page 251: ...Section 9 Sato Group of Companies TG3 Series Service Manual Page 9 1 SATO GROUP OF COMPANIES...