RX610 Group
29. Electrical Characteristics
R01UH0032EJ0120 Rev.1.20
Page 958 of 1006
Feb 20, 2013
29.3
AC Characteristics
Table 29.4 Operation Frequency Value
Conditions: V
CC
= PLLV
CC
= AV
CC
= 3.0 to 3.6 V, V
REFH
= 3.0 V to AV
CC
, V
SS
= PLLV
SS
= V
REFL
= 0 V
T
a
= -20 to +85
°
C (regular specifications), T
a
= -40 to +85
°
C (wide-range specifications)
Item
Symbol
Min.
Typ.
Max.
Unit
Operation
frequency
System clock (ICLK)
f
8
100
MHz
Peripheral module clock (PCLK)
8
50
External bus clock (BCLK)
8
25
29.3.1
Clock Timing
Table 29.5 Clock Timing
Conditions: V
CC
= PLLV
CC
= AV
CC
= 3.0 to 3.6 V, V
REFH
= 3.0 V to AV
CC
, V
SS
= PLLV
SS
= V
REFL
= 0 V
ICLK = 8 to 100 MHz, BCLK = 8 to 25 MHz, PCLK = 8 to 50 MHz
T
a
= -20 to +85
°
C (regular specifications), T
a
= -40 to +85
°
C (wide-range specifications)
Item
Symbol
Min.
Max.
Unit
Test Conditions
Clock cycle time
t
cyc
40
125
ns
Figure 29.1
Clock high pulse width
t
CH
15
ns
Clock low pulse width
t
CL
15
ns
Clock rising time
t
Cr
5
ns
Clock falling time
t
Cf
5
ns
Oscillation settling time after reset (crystal)
t
OSC1
10
ms
Figure 29.4
Oscillation settling time after leaving software
standby mode (crystal)
t
OSC2
10
ms
Figure 29.2
Oscillation settling time after leaving deep software
standby mode (crystal)
t
OSC3
10
ms
Figure 29.3
External clock output delay settling time
t
DEXT
1
ms
Figure 29.4
External clock input low pulse width
t
EXL
30.71
ns
Figure 29.5
External clock input high pulse width
t
EXH
30.71
ns
External clock rising time
t
EXr
5
ns
External clock falling time
t
EXf
5
ns
BCLK
t
CH
t
cyc
t
Cf
t
CL
t
Cr
Test conditions V
OH
= V
CC
× 0.7, V
OL
= V
CC
× 0.3, I
OH
= - 1.0mA, I
OL
= 1.0mA, C = 30pF
Figure 29.1 External Bus Clock Timing
Summary of Contents for RX600 Series
Page 1006: ...RX610 Group R01UH0032EJ0120 ...