20.5.2
Data Format (Except in Block Transfer Mode)
Figure 20.21 shows the data transfer formats in smart card interface mode.
•
One frame consists of 8-bit data and a parity bit in asynchronous mode.
•
During transmission, at least 2 etu (elementary time unit: time required for transferring one bit) is secured as a guard
time from the end of the parity bit until the start of the next frame.
•
If a parity error is detected during reception, a low-level error signal is output for 1 etu after 10.5 etu has passed from
the start bit.
•
If an error signal is sampled during transmission, the same data is automatically re-transmitted after at least 2 etu.
Ds
D0
D1
D2
D3
D4
D5
D6
D7
Dp
In normal transmission/reception
Output from the transmitting station
Ds
D0
D1
D2
D3
D4
D5
D6
D7
Dp
When a parity error is generated
Output from the transmitting station
DE
Output from the
receiving station
[Legend]
Ds:
Start bit
D0 to D7: Data bits
Dp:
Parity bit
DE:
Error signal
Figure 20.21 Data Formats in Smart Card Interface Mode