15.5
DTC Activation
The DTC can be activated by the TPUm.TGRy input capture/compare match interrupt of each channel. For details, see
section 13, Data Transfer Controller (DTC).
A total of 32 input capture/compare match interrupts can be used as DTC activation sources, four each for TPU0 and
TPU3 (TPU6 and TPU9), and two each for TPU1, TPU2, TPU4, and TPU5 (TPU7, TPU8, TPU10, and TPU11).
15.6
DMAC Activation
The DMAC can be activated by the TPUm.TGRA input capture/compare match interrupt of each channel. For details,
see section 12, DMA controller (DMAC).
A total of twelve TPUm.TGRA input capture/compare match interrupts can be used as DMAC activation sources, one for
each channel.
15.7
A/D Converter Activation
The TPU can activate the A/D converter by the TPUm.TGRA input capture/compare match for each channel. Moreover,
the A/D converter is activated by the TGRA to TGRD input capture/compare match from TPU0.*
When the TTGE bit in TPUm.TIER is set to 1, the TPU requests the A/D converter to start A/D conversion by the
occurrence of a TPUm.TGRA input capture/compare match on a particular channel. If the TPU conversion start trigger
has been selected on the A/D converter side at this time, A/D conversion is started. Moreover, the TPU requests the A/D
converter to start A/D conversion by the occurrence of a TGRA to TGRD input capture/compare match from TPU0 . If
the TPU conversion start trigger has been selected on the A/D converter side at this time, A/D conversion is started.
Note: * For the corresponding unit of A/D converter, see section 23, A/D Converter.