RX610 Group
20. Serial Communications Interface (SCI)
R01UH0032EJ0120 Rev.1.20
Page 616 of 1006
Feb 20, 2013
SMR is used to set the SCI's serial transfer format and select the baud rate generator clock source.
CKS[1:0] Bits (Clock Select)
These bits select the clock source for the baud rate generator.
For the relation between the settings of these bits and the baud rate, see section 20.2.9, Bit Rate Register (BRR).
STOP Bit (Stop Bit Length)
Selects the stop bit length in transmission.
In reception, only the first stop bit is checked. If the second stop bit is 0, it is treated as the start bit of the next transmit
frame.
PM Bit (Parity Mode)
Selects the parity mode (even or odd) for transmission and reception.
PE Bit (Parity Enable)
When this bit is set to 1, the parity bit is added to transmit data, and the parity bit is checked in reception.
CHR Bit (Character Length)
Selects the data length for transmission and reception.
In clock synchronous mode, a fixed data length of 8 bits is used.
CM Bit (Communications Mode)
Selects asynchronous or clock synchronous mode.