RX610 Group
20. Serial Communications Interface (SCI)
R01UH0032EJ0120 Rev.1.20
Page 649 of 1006
Feb 20, 2013
Table 20.14 shows the states of the SSR status flags and receive data handling when a receive error is detected.
If a receive error is detected, an ERI interrupt request is generated but an RXI interrupt request is not generated. Data
reception cannot be resumed while the receive error flag is set to 1. Accordingly, clear the ORER, FER, and PER bits to
0 before resuming reception. Moreover, be sure to read the RDR during overrun error processing.
Figure 20.11 shows samples of flowcharts for serial data reception.
Table 20.14 SSR Status Flags and Receive Data Handling
SSR Status Flag
Receive Data
Receive Error Type
ORER
FER
PER
1
0
0
Lost
Overrun error
0
1
0
Transferred to RDR
Framing error
0
0
1
Transferred to RDR
Parity error
1
1
0
Lost
Overrun error + framing error
1
0
1
Lost
Overrun error + parity error
0
1
1
Transferred to RDR
Framing error + parity error
1
1
1
Lost
Overrun error + framing error + parity error