RX610 Group
18. Compare Match Timer (CMT)
R01UH0032EJ0120 Rev.1.20
Page 588 of 1006
Feb 20, 2013
18.2
Register Descriptions
Table 18.2 lists the registers of the CMT.
Table 18.2 List of CMT Registers
Unit
Channel
Register Name
Symbol
Value after
Reset
Address
Access Size
Unit 0
Common
Compare match timer start register 0
CMSTR0
0000h
0008 8000h 16
CMT0
Compare match timer control register
CMCR
00x0h
0008 8002h 16
Compare match timer counter
CMCNT
0000h
0008 8004h 16
Compare match timer constant register
CMCOR
FFFFh
0008 8006h 16
CMT1
Compare match timer control register
CMCR
00x0h
0008 8008h 16
Compare match timer counter
CMCNT
0000h
0008 800Ah 16
Compare match timer constant register
CMCOR
FFFFh
0008 800Ch 16
Unit 1
Common
Compare match timer start register 1
CMSTR1
0000h
0008 8010h 16
CMT2
Compare match timer control register
CMCR
00x0h
0008 8012h 16
Compare match timer counter
CMCNT
0000h
0008 8014h 16
Compare match timer constant register
CMCOR
FFFFh
0008 8016h 16
CMT3
Compare match timer control register
CMCR
00x0h
0008 8018h 16
Compare match timer counter
CMCNT
0000h
0008 801Ah 16
Compare match timer constant register
CMCOR
FFFFh
0008 801Ch 16