RX610 Group
20. Serial Communications Interface (SCI)
R01UH0032EJ0120 Rev.1.20
Page 608 of 1006
Feb 20, 2013
20.
Serial Communications Interface (SCI)
The RX610 Group has seven independent serial communications interface (SCI) units.
The SCI can handle both asynchronous and clock synchronous serial communications.
Asynchronous serial data communications can be carried out with standard asynchronous communications chips such as
a Universal Asynchronous Receiver/Transmitter (UART) or Asynchronous Communications Interface Adapter (ACIA).
The SCI also supports the smart card (IC card) interface supporting ISO/IEC 7816-3 (Identification Card) as an extended
asynchronous communications mode.
20.1
Overview
Table 20.1 lists the specifications of the SCI and table 20.2 lists the functions of each SCI channel.
Figure 20.1 shows a block diagram of the SCI0 to SCI4. Figure 20.2 shows a block diagram of the SCI5 and SCI6.
Table 20.1 Specifications of SCI
Item
Specifications
Serial communications mode
•
Asynchronous
•
Clock synchronous
•
Smart card interface
Transfer speed
Bit rate specifiable with on-chip baud rate generator.
Full-duplex communications
Transmitter: Enables continuous transmission by double-buffering.
Receiver: Enables continuous reception by double-buffering.
Input/output pins
See table 20.3.
Data transfer
Selectable from LSB-first or MSB-first transfer
Interrupt sources
Transmit-end, transmit-data-empty, receive-data-full, and receive error
Power-down function
Module stop state can be set for each unit.
Asynchronous mode
Data length
7 or 8 bits
Transmission stop bit
1 or 2 bits
Parity
Even, odd, or none
Receive error detection
Parity, overrun, and framing errors
Break detection
Break can be detected by reading RxDn (n = 0 to 6) pin level directly in case of
a framing error
Clock source
Selectable from internal or external clock
Enables transfer rate clock input from TMR (SCI5 and SCI6)
Clock synchronous
mode
Data length
8 bits
Receive error detection
Overrun errors
Smart card interface
mode
Error processing
An error signal can be automatically transmitted on detection of a parity error
during reception
Data can be automatically re-transmitted on receiving an error signal during
transmission
Data type
Both direct convention and inverse convention are supported.
Summary of Contents for RX600 Series