RX610 Group
15. 16-Bit Timer Pulse Unit (TPU)
R01UH0032EJ0120 Rev.1.20
Page 505 of 1006
Feb 20, 2013
(b)
Phase counting mode 2
Figure 15.27 shows an example of phase counting mode 2 operation, and table 15.28 lists the TPUm.TCNT
up-/down-count conditions.
TCLKA (TPU1, TPU5)
TCLKC (TPU2, TPU4)
TCLKB (TPU1, TPU5)
TCLKD (TPU2, TPU4)
TCNT value
Up-count
Down-count
Time
Figure 15.27 Example of Phase Counting Mode 2 Operation
Table 15.28 Up-/Down-Count Conditions in Phase Counting Mode 2
TCLKA (TPU1, TPU5)
TCLKC (TPU2, TPU4)
TCLKB (TPU1, TPU5)
TCLKD (TPU2, TPU4)
Operation
High level
Don't care
Low level
Don't care
Low level
Don't care
High level
Up-count
High level
Don't care
Low level
Don't care
High level
Don't care
Low level
Down-count
[Legend]
: Rising edge
: Falling edge