RX610 Group
18. Compare Match Timer (CMT)
R01UH0032EJ0120 Rev.1.20
Page 590 of 1006
Feb 20, 2013
18.2.2
Compare Match Timer Start Register 1 (CMSTR1)
b7
b6
b5
b4
b3
b2
b1
b0
Value after reset:
0
0
0
0
0
0
0
0
—
—
—
—
—
—
STR3
STR2
Address: 0008 8010h
b15
b14
b13
b12
b11
b10
b9
b8
Value after reset:
0
0
0
0
0
0
0
0
—
—
—
—
—
—
—
—
Bit
Symbol
Bit Name
Description
R/W
b0
STR2
Count Start 2
0: CMT2.CMCNT count is stopped
1: CMT2.CMCNT count is started
R/W
b1
STR3
Count Start 3
0: CMT3.CMCNT count is stopped
1: CMT3.CMCNT count is started
R/W
b15 to b2
Reserved
These bits are always read as 0. The write value should
always be 0.
R/W
CMSTR1 selects whether the CMT2.CMCNT or CMT3.CMCNT counter operates or is stopped.
STR2 Bit (Count Start 2)
The STR2 bit specifies whether CMT2.CMCNT operates or is stopped.
STR3 Bit (Count Start 3)
The STR3 bit specifies whether CMT3.CMCNT operates or is stopped.