16.3.8
Pulse Output Triggered by Input Capture
Pulse output from the PPG0 can be triggered by the TPU (unit 0) input capture as well as by compare match. When a
TPUm.TGRA (m = 0 to 3) functions as an input capture register in the TPU (unit 0) channel selected by PPG0.PCR,
pulse output is triggered by the input capture signal.
Figure 16.15 shows the timing of pulse output triggered by input capture.
PCLK
N
M
N
TIOC pin
Input capture signal
NDR
PODR
M
N
PO
Figure 16.15 Timing of Pulse Output Triggered by Input Capture (Example)