RX610 Group
23. A/D Converter
R01UH0032EJ0120 Rev.1.20
Page 796 of 1006
Feb 20, 2013
23.3.5
Activation by the Compare-Match/Input-Capture A to D Signals from TPU0
The compare-match/input-capture A to D signals from TPU0 are capable of starting A/D conversion by units 0 to 3.
The connections between the units of the converter and the compare-match/input-capture A to D signals from TPU0 are
shown in figure 23.10.
The compare-match/input-capture A to D signals from TPU0 are capable of starting A/D conversion by all four converter
units. Setting the AD0.ADCR.TRGS[2:0] bits to 100b (specifying the compare-match/input-capture A signal from
TPU0), setting the AD1.ADCR.TRGS[2:0] bits to 100b (specifying the compare-match/input-capture B signal from
TPU0), setting the AD2.ADCR.TRGS[2:0] bits to 100b (specifying the compare-match/input-capture C signal from
TPU0), and setting the AD3.ADCR.TRGS[2:0] bits to 100b (specifying the compare-match/input-capture D signal from
TPU0) set up the compare-match/input-capture A to D signals from TPU0 as the triggers that start conversion by units 0
to 3.
AD0.ADCR.TRGS[2:0]
A/D conversion start trigger
A/D converter unit 0
TPU unit 0
Compare-match/input-
capture A signal
Compare-match/input-
capture B signal
Compare-match/input-
capture C signal
Compare-match/input-
capture D signal
TPU0
AD1.ADCR.TRGS[2:0]
A/D conversion start trigger
A/D converter unit 1
AD2.ADCR.TRGS[2:0]
A/D conversion start trigger
A/D converter unit 2
AD3.ADCR.TRGS[2:0]
A/D conversion start trigger
A/D converter unit 3
Figure 23.10 Connections between Compare-Match/Input-Capture A to D Signals from TPU0
and the Respective Converter Units
Summary of Contents for RX600 Series
Page 1006: ...RX610 Group R01UH0032EJ0120 ...