ADLINK Technology cPCIS-1100 Series User Manual Download Page 1

 

 
 
 
 

cPCIS-1100 Series 

3U Height Subsystems for 

CompactPCI Modules 

User’s Manual

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

    
         
   

Manual Rev.: 

2.00 

   

Date:    

September 15, 2014  

   

Part Number:

  

50-15091-2000 

 

Summary of Contents for cPCIS-1100 Series

Page 1: ...cPCIS 1100 Series 3U Height Subsystems for CompactPCI Modules User s Manual Manual Rev 2 00 Date September 15 2014 Part Number 50 15091 2000 ...

Page 2: ...e for direct indirect special incidental or consequential damages arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright All rights are reserved No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior writte...

Page 3: ... 2 4 Powering Up the System 9 3 Backplane 11 3 1 cBP 3208 R Backplane 11 Specifications 11 Mechanical Drawing 12 Pin Assignment 14 3 2 cBP 3206 R Backplane 18 Specifications 18 Mechanical Drawing 19 Pin Assignment 20 3 3 cBP 3061 Power Backplane 24 Specifications 24 Mechanical Drawing 24 Pin Assignment 25 3 4 cBP 3062A Power Backplane 28 Specifications 28 Mechanical Drawing 28 Pin Assignment 29 4 ...

Page 4: ... 35 Input Characteristics 35 Output Characteristics 36 4 3 CompactPCI ETT PSU cPS P325 AC 37 Features 37 Specifications 37 Input Characteristics 37 Output Characteristics 38 5 Specifications 41 5 1 Features 41 5 2 Mechanical 41 5 3 Environmental 42 Important Safety Instructions 43 ...

Page 5: ...es and excellent shock and vibration characteristics make it suitable for operation in a rigorous environment The cPCIS ET1100 Series allows for custom configuration giving system integrators maximum flexibility to build in specialized functionality This user s manual provides unpacking operating and maintenance information for the cPCI 1100 Series 3U CompactPCI subsystems The cPCI 1100 Series sub...

Page 6: ...2 x Introduction 1 2 Mechanical Drawing ...

Page 7: ... x 2 5 x 2 250W cPCI 1 1 2 0 2 1 2 11 cPCIS ET1101 1 7 250W ETT cPCI PSU 2 0 2 1 2 11 cPCIS ET1102 1 7 250W ETT 2 x cPCI PSU 2 0 2 1 2 11 All models are available with rear I O backplanes for Rear Transition Modules RTMs and are indicated by an R suffix on the model name 1 4 Customized Systems Sub systems can also be customized to meet individual needs To customize a sub system please contact an A...

Page 8: ...4 x Introduction This page intentionally left blank ...

Page 9: ...tain authorization before returning any product to ADLINK Check that the following items are included in the package If there are any missing items please contact your dealer x One cPCIS 1100 Series sub system x This User s Manual x Power cord either N American or European 2 2 CompactPCI Board PSU Installation cPCIS 1100 Series models with CompactPCI PSU s The CompactPCI connectors are rigid and r...

Page 10: ...lled in a system slot Do not insert a system card into any other slot or insert any peripheral card into system slot The handle on CompactPCI cards and PSUs ensures simple and safe installation and removal Please follow the procedures below to install a CompactPCI module into a cPCIS 1100 Series chassis with CompactPCI PSU s System Card Slot Peripheral Card Slots PSU Slot ...

Page 11: ...or PSU modules make sure that the handle is unlatched i e that it is pulled downwards by first pressing on the locking button with your thumb 3 Carefully insert the module into the desired slot by sliding the edges of the board into the appropriate card guide rail Take care to ensure correct alignment of the card with the chassis during insertion to prevent damage to the card and or backplane 4 Co...

Page 12: ...tarted To remove the module press the release button if necessary and reverse steps 1 through 5 above 2 3 RTM Rear Transition Module Installation Fully Latched Handle Engages with Chassis System Card Fully Inserted ...

Page 13: ... or removing RTMs Only models with an R at the end of the model number support RTMs Note We strongly recommended the use of RTMs with AB type connectors to prevent damaging the backplane during RTM installation 2 4 Powering Up the System Connect the supplied power cord to the socket on the back of the chassis All supplied PSUs are full range 90 240VAC and do not require input voltage setting ...

Page 14: ...10 x Getting Started This page intentionally left blank ...

Page 15: ...S ET1101 cBP 3208 8 cBP 3061 cPCIS ET1102 cBP 3208 8 cBP 3062A 3 1 cBP 3208 R Backplane The cBP 3208 R is a 3U CompactPCI 32 bit backplane with optional rear I O designated by an R suffix It is used by the cPCIS 1100A cPCIS 1101 cPCIS 1102 cPCIS ET1101 cPCIS ET1102 Specifications Standard CompactPCI height for 3U cPCI cards CompactPCI Compliancy PICMG 2 0 CompactPCI core specification R3 0 PICMG 2...

Page 16: ...l Slots Rear I O P2 rear I O with AB type shroud optional Power Connectors ATX connector x2 DC screw terminals V I O 3 3V or 5V selectable default 5V Other connectors INH Reset PWR_FAL Mechanical Drawing cBP 3208 R Front View 1 P2 1 P1 8 P2 8 P1 ...

Page 17: ...Backplane x 13 cBP 3208 R Rear View 1 P2 Optional Rear I O 2 P2 to 8 P2 ...

Page 18: ...GND 17 GND 3 3V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY BDSEL TRDY GND 12 14 Key 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 IDSEL AD 23 GND AD 22 GND 8 GND AD 26 GND V I O AD 25 AD 24 GND 7 GND AD 30 AD 29 AD 28 GND AD 27 GND 6 GND REQ GND 3 3V CLK AD 31 GND 5 GND Reserved Reserved PCIRST GND GNT GN...

Page 19: ...NC NC GND 15 GND NC NC FAL REQ5 GNT5 GND 14 GND NC NC NC NC NC GND 13 GND NC NC NC NC NC GND 12 GND NC NC NC NC NC GND 11 GND NC NC NC NC NC GND 10 GND NC NC NC NC NC GND 9 GND NC NC NC NC NC GND 8 GND NC NC NC NC NC GND 7 GND NC NC NC NC NC GND 6 GND NC NC NC NC NC GND 5 GND NC NC NC NC NC GND 4 GND V I O NC NC NC NC GND 3 GND CLK4 GND GNT3 REQ4 GNT4 GND 2 GND CLK2 CLK3 GND GNT2 REQ3 GND 1 GND CL...

Page 20: ...6 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY GND TRDY GND 12 14 Key 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 IDSEL AD 23 GND AD 22 GND 8 GND AD 26 GND V I O AD 25 AD 24 GND 7 GND AD 30 AD 29 AD 28 GND AD 27 GND 6 GND REQ GND 3 3V CLK AD 31 GND 5 GND NC NC PCIRST GND GNT GND 4 GND IPMB_PWR HEALTHY V I O INTP INTS GND 3 GND INTA INTB I...

Page 21: ...GND 17 GND 8 POWER GOOD 18 5V 9 5V STB 19 5V 10 12V 20 5V JP7 connector Pin Signal Name 1 12V 2 12V Sense JP8 connector Pin Signal Name 1 INH 2 GND JP9 connector Pin Signal Name 1 PRST 2 GND JP10 connector Pin Signal Name 1 FAL 2 GND JP1 V I O default 5V Pin Signal Name Pin Signal Name 1 12V 2 GND 3 12V 4 GND 5 3 3V 6 GND 7 5V 8 GND 1 11 1 8 1 1 1 1 ...

Page 22: ...I Compliancy PICMG 2 0 CompactPCI core specification R3 0 PICMG 2 1 CompactPCI hot swap R2 0 Dimensions 100 7 x 128 7 mm PCI bus clock up to 32 bit 33MHz System Slot one R hand side dual slot System Slot Rear I O P2 rear I O with AB type shroud Peripheral slots 5 Peripheral Slots Rear I O P2 rear I O with AB type shroud optional Power Connectors ATX connector x2 DC screw terminals V I O 3 3V or 5V...

Page 23: ...Backplane x 19 Mechanical Drawing cBP 3206 R Rear View cBP 3206 R Front View 1 P2 1 P1 6 P2 6 P1 CN1 CN2 JP8 JP10 1 P2 Opt Rear I O 2 P2 to 6 P2 ...

Page 24: ...GND 17 GND 3 3V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY BDSEL TRDY GND 12 14 Key 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 IDSEL AD 23 GND AD 22 GND 8 GND AD 26 GND V I O AD 25 AD 24 GND 7 GND AD 30 AD 29 AD 28 GND AD 27 GND 6 GND REQ GND 3 3V CLK AD 31 GND 5 GND Reserved Reserved PCIRST GND GNT GN...

Page 25: ...NC NC GND 15 GND NC NC FAL REQ5 GNT5 GND 14 GND NC NC NC NC NC GND 13 GND NC NC NC NC NC GND 12 GND NC NC NC NC NC GND 11 GND NC NC NC NC NC GND 10 GND NC NC NC NC NC GND 9 GND NC NC NC NC NC GND 8 GND NC NC NC NC NC GND 7 GND NC NC NC NC NC GND 6 GND NC NC NC NC NC GND 5 GND NC NC NC NC NC GND 4 GND V I O NC NC NC NC GND 3 GND CLK4 GND GNT3 REQ4 GNT4 GND 2 GND CLK2 CLK3 GND GNT2 REQ3 GND 1 GND CL...

Page 26: ...6 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY GND TRDY GND 12 14 Key 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 IDSEL AD 23 GND AD 22 GND 8 GND AD 26 GND V I O AD 25 AD 24 GND 7 GND AD 30 AD 29 AD 28 GND AD 27 GND 6 GND REQ GND 3 3V CLK AD 31 GND 5 GND NC NC PCIRST GND GNT GND 4 GND IPMB_PWR HEALTHY V I O INTP INTS GND 3 GND INTA INTB I...

Page 27: ...3 3V 2 3 3V 12 12V 3 GND 13 GND 4 5V 14 PS_ON_L 5 GND 15 GND 6 5V 16 GND 7 GND 17 GND 8 POWER GOOD 18 5V 9 5V STB 19 5V 10 12V 20 5V JP8 connector Pin Signal Name 1 INH 2 12V Sense JP9 connector Pin Signal Name 1 PRST 2 GND JP10 connector Pin Signal Name 1 FAL 2 GND 1 11 1 1 1 ...

Page 28: ...cPCIS 1202 Specifications CompactPCI Compliancy PICMG 2 11 CompactPCI Power Interface Dimensions 39 64x 128 7 mm Power Module Sockets one AC DC input screw terminal yes DC output ATX connector one Cascading voltage Sense Built in ATX connector INH FAL DEG Distribution Built in ATX connector Mechanical Drawing cBP 3061 R Rear View cBP 3061 R Front View CN2 CN5 CN6 CN8 CN9 CN1 CN3 CN4 CN7 ...

Page 29: ...ent CN1 Power Sense Connector Pin Signal Name 1 V1_Sense 2 GND_S 3 V2_Sense 4 V3_Sense 5 NC CN2 Power Sense Connector Pin Signal Name 1 V1_Sense 2 GND_S 3 V2_Sense 4 V3_Sense 5 NC CN3 connector Pin Signal Name 1 INHJ 2 GND 1 1 1 ...

Page 30: ...D 41 V2 SHARE 25 GA0 40 IPMB_SDA 24 RTN 39 INH 23 RESERVED 38 DEG 22 RTN 37 IPMB_SCL 21 V4 36 V3 SENSE 20 V3 35 V1 SHARE 19 RTN 34 S RTN 13 18 V2 33 V2 SENSE 5 12 RTN 32 V2ADJ 1 4 V1 CN5 Current Share Connector Pin Signal Name 1 V1_Share 2 GND 3 V2_Share 4 V3_Share 5 NC CN6 Current Share Connector Pin Signal Name 1 V1_Share 2 GND 3 V2_Share 4 V3_Share 5 NC 2 1 20 19 44 42 47 23 21 1 1 ...

Page 31: ...ND CN8 IPMB Connector Pin Signal Name 1 IPMB_SCL 2 GND 3 IPMB_SDA 4 IPMB_PWR 5 ALERT CN9 ATX Power Connector Pin Signal Pin Signal 1 3 3V 11 3 3V 2 3 3V 12 12V 3 GND 13 GND 4 5V 14 PS_ON_L 5 GND 15 GND 6 5V 16 GND 7 GND 17 GND 8 POWER GOOD 18 5V 9 5V STB 19 5V 10 12V 20 5V 1 11 1 1 ...

Page 32: ...wer Interface Dimensions 80 28 x 128 7 mm Power Module Sockets two AC DC input screw terminal yes DC output ATX connector two Cascading Current Sharing yes Cascading Voltage Sense Built in ATX connector INH FAL DEG Distribution Selectable common INH FAL DEG or separated INH for each power module dedicated connector PICMG 2 0 IPMB Socket yes Mechanical Drawing cBP 3062 R Rear View cBP 3062 R Front ...

Page 33: ...N 42 FAL 26 RESERVED 41 V2 SHARE 25 GA0 40 IPMB_SDA 24 RTN 39 INH 23 RESERVED 38 DEG 22 RTN 37 IPMB_SCL 21 V4 36 V3 SENSE 20 V3 35 V1 SHARE 19 RTN 34 S RTN 13 18 V2 33 V2 SENSE 5 12 RTN 32 V2ADJ 1 4 V1 CN3 AC DC in Let Connector Pin Signal Name 1 ACN DC 2 ACL DC 3 CGND CN4 Power Sense Connector Pin Signal Name 1 V1_Sense 2 GND_S 3 V2_Sense 4 V3_Sense 5 NC 2 1 20 19 44 4 2 47 23 21 1 1 ...

Page 34: ..._S 3 V2_Sense 4 V3_Sense 5 NC CN6 Connector Pin Signal Name 1 IPMB_SCL 2 GND 3 IPMB_DA 4 IPMB_PWR 5 ALERT CN7 Current Share Connector Pin Signal Name 1 V1CS 2 GND_S 3 V2 CS 4 V3 CS 5 NC CN8 Current Share Connector Pin Signal Name 1 V1 CS 2 GND_S 3 V2 CS 4 V3 CS 5 NC 1 1 1 1 ...

Page 35: ... GND 15 GND 6 5V 16 GND 7 GND 17 GND 8 POWER GOOD 18 5V 9 5V STB 19 5V 10 12V 20 5V JP1 connector Pin Signal Name 1 INH 2 2 GND JP2 connector Pin Signal Name 1 INH 1 2 GND JP3 connector Pin Signal Name 1 DEG 1 2 FAL 1 3 RSV23A 4 RSV26A 5 DEG 2 6 FAL 2 7 RSV23B 8 RSV26B JP4 connector Pin Signal Name 1 INH 2 GND 1 11 1 1 1 1 8 ...

Page 36: ...32 x Backplane This page intentionally left blank ...

Page 37: ...ture Range 10 C 45 C x Cooling one 80mm DC fan x Active Power Factor Correction meets IEC 1000 3 2 CLASS D x Dimensions 140 00x150 00x86 00 mm x Hold Up Time 16 ms minimum at full load normal input voltage x Dielectric Withstand input output 1500 VAC for 1 second input to frame ground 1500 VAC for 1 second x Efficiency 70 typical at 115V full load x Power Good Signal on delay 100 ms to 500 ms off ...

Page 38: ...30 VAC x Inrush Current 65A MAX FOR 115 VAC 125A MAX FOR 230 VAC Output Characteristics Output Current A Regulation Output Output Voltage MIN MAX PEAK LOAD LINE Ripple Noise Max P P 5V 3 35 5 1 50mV 12V 2 30 7 5 1 120mV 5V 0 0 5 5 1 150mV 12V 0 0 8 5 1 150mV 3 3V 1 28 5 1 50mV 5VSB 0 1 2 5 1 50mV Note The output current of 5V 3 3V must not exceed 45A ...

Page 39: ...C x Cooling 20 CFM moving air required to achieve full rated power x Dimensions Eurocard 3U X 8HP X 160mm CompactPCI format x Efficiency 78 79 typical x Switching Frequency 120K Hz x Safety IEC60950 Class I x Circuit Topology Forward circuit x Transient Response Peak transient less than 100mV and recovers within 2mS after 25 load change Input Characteristics x Input Voltage Typ 90 264VAC x Power F...

Page 40: ...puts x Leakage Current Typ 0 5mA Output Characteristics Output Current A Output Voltage MIN MAX TYP PEAK 5V MAIN VO1 Ϫ Ł Ф 2 0 33 0 25 0 3 3V AUX VO2 Ÿ Ϫ Ł Ф 0 33 18 12V AUX VO3 Ÿ Ł Ф Ϫ 0 5 5 5 5 6 12V AUX VO4 Ɣ Ф Ϫ Ŷ 0 1 0 5 1 5 Symbol Ϫ OVP built in Adjustable Remote sensing Ł 3rd wire Load Sharing Droop Current Sharing Ф Installed with Or ing diode Ÿ Magnetic Amplifier Ɣ Installed with Post reg...

Page 41: ... C x Cooling 400 LFM moving air required to achieve full rated power x Dimensions Eurocard 3U x 8HP x 160mm CompactPCI format x Efficiency 81 5 82 6 typical x Switching Frequency 135K Hz x Safety IEC60950 1 CSA60950 1 China CCC x Circuit Topology forward circuit Input Characteristics x Input Voltage Typ 90 264VAC x Power Factor Correction meets Harmonic Correction EN 61000 3 2 x Input Connector Co...

Page 42: ...ort circuit typical 120 max load Over Current Protection installed at each rail o Output Wattage Typ 250W continuous o Output Connector CompactPCI 47 pin power connector o Line Regulation Max 10mV o Load Regulation 3 3V 5V 10mV 12V 30mV 12V 380 mV o Noise Ripple 60 mV 5V and 3 3V output 120mV 12V output o OVP Built in at all outputs o Adjustability Available at VO1 2 3 o Output Trim Electrical tri...

Page 43: ...upply Unit x 39 o Over Current Protection Installed at each rail o Overload Protection Fully protected against output overload or short circuit Typical 120 max load Output power versus temperature TA at Vi nom ...

Page 44: ...40 x Power Supply Unit This page intentionally left blank ...

Page 45: ...assis Suitable for rack mount Comprehensive EMC shielding EMC gaskets are installed on front rails top and bottom rear rails and side panels Power switch At least 400 LFM external cooling fans are required 5 2 Mechanical CompactPCI Standard 2 0 R3 0 Form Factor 3U CompactPCI with 50mm depth rear I O Enclosure 19 3U height rack mount enclosure Dimensions 482 56mm W x 133 35mm H x 250mm D Usable wid...

Page 46: ...ng issue when above 50 C Power efficiency will be derating 2 5 every Celsius degree and it will only have 50 of power efficiency when 70 C Storage Temperature 40 C to 85 C Humidity 5 95 non condensed Shock 15G peak to peak 11ms duration non operation Vibration o Non operation 1 88Grms 5 500Hz each axis Operation 0 5Grms 5 500Hz each axis ...

Page 47: ...ocket outlet shall be installed near the equipment and shall be easily accessible z Place the power cord such a way that people can not step on it Do not place anything over the power cord z If the equipment is not use for long time disconnect the equipment from mains to avoid being damaged by transient overvoltage z All cautions and warnings on the equipment should be noted z Please keep this equ...

Page 48: ...ice personnel A The power cord or plug is damaged B Liquid has penetrated into the equipment C The equipment has been exposed to moisture D The equipment has not work well or you can not get it work according to user s manual E The equipment has dropped and damaged F If the equipment has obvious sign of breakage ...

Reviews: