SRK-C
3.1
GENERAL INFORMATION
3.1.1 Specific features
The “Mitsubishi Daiya” room air conditioner:
SRK series
are of split and wall mounted type and the unit consists of indoor unit
and outdoor unit with refrigerant precharged in factory. The indoor unit is composed of room air cooling or heating equipment
with operation control switch and the outdoor unit is composed of condensing unit with compressor.
(1)
Remote control flap
The flap can be automatically controlled by operating wireless remote control.
• AUTO (Natural flow) : Flap operation is automatically controlled.
• Swing
: This will swing the flap up and down.
• Memory flap
: Once the flap position is set , the unit memorizes the position and continues to operate at the
same position from the next time.
(2)
Automatic Operation
When the remote control switch is set on “ auto ”, it will either automatically decide operation mode such as cooling, heating
and thermal dry, or operate in the operation mode before it has been turned to automatic control.
(3)
Self diagnosis Function
We are constantly trying to do better service to our customers by installing such judges that show abnormality of operation as
follows.
3.1.2. How to read the model name
Example : SR K 50 1 C EN F – L
CE marking model
Flare connecting
Applicable power source . . . See the specifications
Cooling only type
Series No.
Product capacity
Wall mounted type room air-conditioner
Split type room air-conditioner
TIMER lamp is
light up.
RUN lamp is
light up.
RUN lamp is flashing.
(1 Time flash.)
RUN lamp is flashing.
(2 Time flash.)
RUN lamp is flashing.
(6 Time flash.)
TIMER lamp is flashing.
(5 Time flash.)
Abnormality of heat
exchanger thermistor.
No lamps will flashing when
the unit is operating
Abnormality of room
temperature thermistor.
Abnormality of
indoor fan motor.
Abnormality of
outdoor unit.
Summary of Contents for SRRM40HENG-L
Page 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Page 52: ...50 SRK GZ MEMO ...
Page 94: ...92 SRK H MEMO ...
Page 104: ...102 102 SRK C MEMO ...
Page 180: ...178 SCM HG 4room MEMO ...
Page 222: ...220 SCM HG 2room MEMO ...
Page 234: ...232 SCM CG 2room MEMO ...
Page 266: ...SCM C 264 MEMO ...
Page 406: ...404 FDT N C MEMO ...
Page 442: ...440 FDEN H MEMO ...
Page 470: ...468 FDEN C MEMO ...
Page 504: ...502 FDKN H MEMO ...
Page 580: ...578 FDR H MEMO ...
Page 698: ...696 V MULTI Models FDR258 A 308 A ...
Page 724: ...722 V MULTI MEMO ...
Page 1094: ...1092 FDC HKXR MEMO ...