433
FDEN-H
CnL
Receiver
amp
Wireless
remote controller
LED1
LED2
SW
TB
RD/WH
BK/WH
BK/RD
BL/WH
BR/WH
Y/GN
BK
DR
DR
Tho-R
63H
2
CnL
LED-R
LED-G
(Check)
(Run)
CnE
Vao
(Checker)
CnA1
Tro
CnA2
BK
Tho-D
BK
Tho-A
6
14V
27
BL/WH
BK/RD
BR/WH
BL
BL
BL
BL
P
P
BR
BR
BK
BK
26
25
23
22
21
20
19
18
17
16
13
12
2
1
13
24
5
6
Printed wiring board
3
HL
U
H
A1
CF
01
A2
28
X
02
X
01
X
03
X
04
X
06
X
08
X
07
X
01
220/240V
7
PC
PC
CnR
CnM
1
CH
X
04
X
07
X
02
X
05
X
08
X
03
X
06
BR
BR
63H
1
89
1
2/N
3
4
5
F(3.15A)
OR/WH
OR/WH
OR
OR
WH
BR
BL
BK
BL
RD
Y/GN
WH
WH
BL
RD
WH
BL
BK/WH
RD
CT2
CT1
V
UW
52C
RD/WH
RD
BK/WH
WH
L
3
L
1
N
L
2
TB
SV
2
SV
1
52C
20S
FM
O1
(49F
O1
)
CM
PC
PC
PC
X
4
X
3
Y/GN
Y/GN
WH
WH
RD
BR
RD
BK
1
2
3
4
5
TB
BR
Y/GN
BL
BK
1
13
9
11
12
34
76
Val
8
GR
OR
RD
BK
RD
BK
RD
BK
OR
WH
WH
WH
10
WH
RD
OR
BK
OR
BK
OR
H
5
L
H
L
BK
OR
WH
WH
BK
X1
X
1
X
2
X4
X2
X5
X3
X6
LM
CnT
CnH
CnL
CnV
CnB
2
CnN
CnH
2
Th
I
–A
Th
I
–R
BK
BK
BK
BK
RD
RD
BK
BK
XR1
XR2
XR3
XR4
XR5
Option
( 3 )
( 3 )
SW3
ON
OFF
1 2 3 4
Printed wiring board
BK
RD
BK
BR
CnW
1
CnW
2
CnQ
Tr
I
Test
220/240V
14V
8V
CnF
3
CnF
2
CnJ
CnJ
CnF
3
CnF
2
CF
I2
CF
I1
CnF
2
CnF
3
FM
I1
( 49F
I
)
FM
I2
( 49
F
I
)
X
5
X
6
Outdoor Unit
Indoor Unit
WH
BK
BK
NR
Model FDENP308HES-S
Power source
3 Phase 380/415V 50Hz
Color mark
Mark
Color
BK
Black
BL
Blue
BR
Brown
GR
Gray
OR
Orange
P
Pink
RD
Red
WH
White
Mark
Color
BK/RD
Black/Red
BK/WH
Black/White
BL/WH
Blue/White
BR/WH
Brown/White
OR/WH
Orange/White
RD/WH
Red/White
Y/GN
Y
ellow/Green
Meaning of marks
Mark
Parts name
Mark
Parts name
CF
1,2
Capacitor for FM
I
Tho-A
Thermistor
CF
O1
Capacitor for FM
O
Tho-D
Thermistor
CH
Crankcase heater
Tho-R
Thermistor
CM
Compressor motor
Tr
I
T
ransformer (Indoor unit)
CnA ~ Z
Connector (
mark)
Tr
O
T
ransformer (Outdoor unit)
CT
1,2
Current sensor
Va
l
V
aristor
F
Fuse
Va
o
V
aristor
FM
I1,2
Fan motor (Indoor unit)
20S
4-way valve solenoid
FM
O1
Fan motor (Outdoor unit)
49F
I
Internal thermostat for FM
I
LED1
Indication lamp (Green - Run)
49F
O1
Internal thermostat for FMo
LED2
Indication lamp (Y
ellow - Check)
52C
Magnetic contactor for CM
LM
Louver motor
X1~6
Auxiliary relay
NR
Sur
ge suppressor
X
01~08
Auxiliary relay
PC
Photo coupler
63H
1
High pressure switch (for protection)
SV
1,2
Solenoid coil (for control)
63H
2
High pressure switch (for control)
SW
Switch (ON/OFF)
v
T
erminal (F)
SW3
Changeover switch
■
Connector
TB
T
erminal block (
mark)
LED-G
Indication lamp (Green)
Th
I
-A
Thermistor
LED-R
Indication lamp (Red)
Th
I
-R
Thermistor
Summary of Contents for SRRM40HENG-L
Page 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Page 52: ...50 SRK GZ MEMO ...
Page 94: ...92 SRK H MEMO ...
Page 104: ...102 102 SRK C MEMO ...
Page 180: ...178 SCM HG 4room MEMO ...
Page 222: ...220 SCM HG 2room MEMO ...
Page 234: ...232 SCM CG 2room MEMO ...
Page 266: ...SCM C 264 MEMO ...
Page 406: ...404 FDT N C MEMO ...
Page 442: ...440 FDEN H MEMO ...
Page 470: ...468 FDEN C MEMO ...
Page 504: ...502 FDKN H MEMO ...
Page 580: ...578 FDR H MEMO ...
Page 698: ...696 V MULTI Models FDR258 A 308 A ...
Page 724: ...722 V MULTI MEMO ...
Page 1094: ...1092 FDC HKXR MEMO ...