538
FDR-H
Item
Model
FDR408-A
FDC406HES3
Decorative panel
Panel model (Option)
Nominal cooling capacity
(1)
W
10200
Nominal heating capacity
(1)
W
10500
Power source
3 Phase, 380/415V, 50Hz
Cooling input
kW
3.76/3.76
Running current (Cooling)
A
7.3/7.3
Power factor (Cooling)
%
78/72
Heating input
kW
3.46/3.46
Running current (Heating)
A
7.0/7.0
Power factor (Heating)
%
75/69
Inrush current
A
45
Noise level
dB(A)
57
Exterior dimensions
mm
1250
×
950
×
340
Height
×
Width
×
Depth
Net weight
kg
86
Refrigerant equipment
—
RC5547ESE1
×
1
Compressor type & Q’ty
Motor
kW
—
2.61
Starting method
—
Line starting
Heat exchanger
Louver fines & inner grooved tubing
Slitted fines & bare tubing
Refrigerant control
Capillary tube
Refrigerant
R22
Quantity
kg
Holding charged
1.6 [Pre-charged up to the piping length of 0m]
Refrigerant oil
r
—
1.63 (SUNISO 3GS)
Defrost control
IC controlled de-icer
High pressure control
High pressure regulator valve
Air handling equipment
Multiblade centrifugal fan
×
3
Propeller fan
×
2
Fan type & Q’ty
Motor
W
45
×
1 + 90
×
1
60
×
2
Starting method
Line starting
Air flow (Standard)
CMM
Hi: 28 Lo: 22
100
Available static pressure
Standard: 50 (5.0) High: 80 (8.0)
—
Fresh air intake
Available
—
Air filter, Q’ty
Polypropylene net
×
3 (washable)
—
Shock & vibration absorber
Rubber sleeve (for fan motor)
Rubber mount (for compressor)
Electric heater
W
—
40 (Crank case heater)
Operation control
Wired remote control switch
Operation switch
(Optional : RCD-H-E)
— (Indoor unit side)
Room temperature control
Thermostat by electronics
—
Safety equipment
Installation data
mm
Liquid line:
φ
9.52 (3/8
″
) Gas line:
φ
19.05 (3/4
″
)
Refrigerant piping size
(in)
Connecting method
Flare piping
Drain hose
(Connectable with VP25)
—
Insulation for piping
Necessary (both Liquid & Gas lines)
Accessories
Mounting kit, Drain hose
Optional parts
Decorative Panel
Model FDR408HES-A
(2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. JIS B8616 "UNITARY AIR-CONDITIONERS"
(3) The operation data indicate when the air-conditioner is operated at 380/415V 50Hz.
(4) Canvas panel is used in combination with following canvas duct. Canvas duct: HA01503
(5) Main unit height of canvas specification type is higher than the other type for canvas duct portion.
Notes (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27˚C
19˚C
35˚C
24˚C
Heating
20˚C
—
7˚C
6˚C
ISO-T1, JIS B8616
Operation data
(3)
Internal thermostat for fan motor.
Frost protection thermostat.
Silent panel
R-PNLS-46W-E
Canvas panel
R-PNLC-46W-E
_
_
Hi: 45 Lo: 38
Hi: 46 Lo: 39
Unit: 406
×
1370
×
635
Panel: 10
×
1660
×
750
Unit: (350
+α
)
×
1370
×
635
Panel: 10
×
1484
×
585
Unit: 50
Panel: 9
Unit: 50
Panel: 7
Pa
(mmAq)
FDR408HES-A
Internal protector for compressor.
Internal thermostat for fan motor.
Internal Pressure relief valve for compressor.
Summary of Contents for SRRM40HENG-L
Page 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Page 52: ...50 SRK GZ MEMO ...
Page 94: ...92 SRK H MEMO ...
Page 104: ...102 102 SRK C MEMO ...
Page 180: ...178 SCM HG 4room MEMO ...
Page 222: ...220 SCM HG 2room MEMO ...
Page 234: ...232 SCM CG 2room MEMO ...
Page 266: ...SCM C 264 MEMO ...
Page 406: ...404 FDT N C MEMO ...
Page 442: ...440 FDEN H MEMO ...
Page 470: ...468 FDEN C MEMO ...
Page 504: ...502 FDKN H MEMO ...
Page 580: ...578 FDR H MEMO ...
Page 698: ...696 V MULTI Models FDR258 A 308 A ...
Page 724: ...722 V MULTI MEMO ...
Page 1094: ...1092 FDC HKXR MEMO ...