(c) Installation
1) Use an attached pattern sheet and mark the position of screws to attach the mounting plate.
2) Determine the direction to lead the pipe and bore a through hole on the wall aligning with the pipe hole of unit.
3) Remove screws (2 pcs.) and remove the right and left
panels from the Indoor unit. ( Remove screws first, move
slightl to remove.)
4) Remove the lower panel from the Indoor unit. It can be
remove if 3 screws are loosened but not removed.
5) Secure the mounting plate with screws at a selected
place on the wall. When the wall is made of concrete,
use the marketed anchor bolts (M6)
Wall
Wall
Outdoor
Indoor
ø 70 mm
Sleeve
Sleeve
Cut the sleeve for the thickness
of wall and insert in the hole.
Sealing
plate
Front
1
2