56
SRK-H
Item
Model
SRK501HENF
–
L
SRC501HENF
–
L
Cooling capacity
(1)
W
4500/4500
Heating capacity
(1)
W
5700/5800
Power source
1 Phase, 220/240V, 50Hz
Cooling input
kW
1.78/1.88
Running current (Cooling)
A
8.4/8.2
Heating input
kW
1.76/1.89
Running current (Heating)
A
8.5/8.3
Inrush current
A
39/42
COP (In cooling)
2.53/2.39
Noise level
(5)
dB(A)
Cooling: 44/44
Heating: 45/45
Cooling: 50/51
Heating: 53/54
Exterior dimensions
Height x Width x Depth
mm
275
‚
790
‚
189
615
‚
850
‚
290
+
30
Color
Ivory white
Polar white
Net weight
kg
9
53
Refrigerant equipment
Compressor type & Q’ty
–
RM5523GNE4 (Rotary type) x 1
Motor
kW
–
1.7
Starting method
–
Line starting
Heat exchanger
Louver fins & bare tubing
Refrigerant control
Capillary tubes
Refrigerant
(4)
kg
R22 1.28
Refrigerant oil
R
0.7 (BARREL FREEZE 32SAM)
Defrost control
MC control
Air handling equipment
Fan type & Q’ty
Tangential fan x 1
Propeller fan x 1
Motor
W
23
40
Air flow (at High)
(Cooling)
11/11
34/34
(Heating)
CMM
12/12
34/34
Air filter, Q’ty
Polypropylene net (washable) x 2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Operation switch
Wireless–Remote controller
–
Room temperature control
MC. Thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow),
–
ECONO (Orange), HI POWER (Green)
Safety equipment
–
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
O.D
mm(in)
Liquid line: ø6.35 (1/4")
Gas line: ø12.7 (1/2")
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.4m
Gas line: 0.35m
–
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source cord
2.5m (3 cores with Earth)
Connection
Size x Core number
1.5mm
2
x 5 cores (With Earth)
wiring
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit
Optional parts
–
Notes
(1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27ºC
19ºC
35ºC
24ºC
JIS C9612, ISO-T1
Heating
20ºC
–
7ºC
6ºC
JIS C9612, ISO-T1
(2) The operation data are applied to the 220V or 240V districts respectively
(3) Limitation of Voltage application Minimum: 198V Maximum: 264V
(4) The refrigerant quantity to be charged includes the refrigerant in 7.5m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, (when it is 10 m, add 20g refrigerant per meter and when it is 10 to 15m, add 30g refrigerant per
meter.)
(5) Expressed in sound pressure level.
Operation data
(1)
Refrigerant
piping
Model SRK501HENF-L (Indoor unit)
SRC501HENF-L (Outdoor unit)
Summary of Contents for SRRM40HENG-L
Page 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Page 52: ...50 SRK GZ MEMO ...
Page 94: ...92 SRK H MEMO ...
Page 104: ...102 102 SRK C MEMO ...
Page 180: ...178 SCM HG 4room MEMO ...
Page 222: ...220 SCM HG 2room MEMO ...
Page 234: ...232 SCM CG 2room MEMO ...
Page 266: ...SCM C 264 MEMO ...
Page 406: ...404 FDT N C MEMO ...
Page 442: ...440 FDEN H MEMO ...
Page 470: ...468 FDEN C MEMO ...
Page 504: ...502 FDKN H MEMO ...
Page 580: ...578 FDR H MEMO ...
Page 698: ...696 V MULTI Models FDR258 A 308 A ...
Page 724: ...722 V MULTI MEMO ...
Page 1094: ...1092 FDC HKXR MEMO ...