962
FDC-HKXR
Item
W
W
kg
kW
RS5555HAS11
RS5570HAS11
340
dB(A)
%
W
kg
W
CMM
175
mm(in)
mm
Models
FDCP2501HKXRE2
(3)
28000
FDCP2001HKXRE2
(3)
22400
25000
3 Phase 380/415V 50Hz
Direct start
Direct start
Brazing
Discharge gas side connection piping (for pervice valve and back direction connections),
intake gas side connection piping (for operation valve and back direction connections)
FDTJ28, 36, 45, 56, 71, 90, 112, 140HKXE2
FDTWJ28, 45, 56, 71, 90, 112, 140HKXE2B
FDTSJ22, 28, 36, 45, 71HKXE2B
FDRJ22, 28, 45, 56, 71, 90, 112, 140HKXE2
FDUMJ36, 45, 56, 71, 90, 112, 140HKXE2
FDEJ36, 45, 56, 71, 112, 140HKXE2B
FDKJ22, 28, 36, 45, 56, 71HKXE2
FDFLJ28, 45, 71HKXE2
FDFUJ28, 45, 56, 71HKXE2
Hole for drain( 20 6pcs)
Necessary (both Liquid &Gas lines)
60
31500
(2) Outdoor unit
Models FDCP2001HKXRE2, 2501HKXRE2
361
2.5 (MA32)
11
100 ~ 22.0
40
5.5
R407C
7.5
1700 1350 600
Nominal cooling capacity*
1
Power source
Nominal heating capacity*
2
Net weight
Capacity control
Crankcase heater
Heat exchanger
Refrigerant control
Refrigerant
Quantity
Refrigerant oil
Defrost control
Starting method
Exterior dimensions
Height Width Depth
Refrigerant equipment
compressor type & Q' ty
Noise level
Motor
(1) The cooling and heating capabilities imply the values when the indoor unit of rated capacity is connected under the condition specified in JIS-B8616.
Flow divide controller part No. list
(2) The refrigerant quantity in the connecting pipe is not included Charge it additionally at the site.
(4) When an individual flow divide controller is used a pipe part set is required.
Notes
(3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which
require CE marking.
Type
Individual flow divide controller
HPFD01R-E
FDCP2001,2501
Part No.
Type
For 3 pipes (for horizontal division)
For 3 pipes (for vertical division)
DIS-IKXR3-E
DIS-VIKXR3-E
FDCP2001,2501
Part No.
Air handling equipment
Fan type & Q'ty
Motor
Starting method
Air flow(Standard)
Shock & vibration absorber
Rubber mount (for compressor)
Compressor overheat protection, overeurrent protection, power transformer overheating
protection, abnormal high pressure protection
Safety equipment
Connecting method
Drain
Insulation for piping
Accessories
Indoor units to be combined
Installation data
Refrigerant piping size
Expansion Valve +Capillary tube
MC controlled De-Icer
Louver fines & inner grooved tubing
Centrifugal fan 2
100 2
Liquid line: 12.7(1/2")
Intake line: 25.4(1")
Discharge line: 19.05(3/4")
Liquid line: 12.7(1/2")
Intake line: 28.58(11/8")
Discharge line: 19.05(3/4")
Summary of Contents for SRRM40HENG-L
Page 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Page 52: ...50 SRK GZ MEMO ...
Page 94: ...92 SRK H MEMO ...
Page 104: ...102 102 SRK C MEMO ...
Page 180: ...178 SCM HG 4room MEMO ...
Page 222: ...220 SCM HG 2room MEMO ...
Page 234: ...232 SCM CG 2room MEMO ...
Page 266: ...SCM C 264 MEMO ...
Page 406: ...404 FDT N C MEMO ...
Page 442: ...440 FDEN H MEMO ...
Page 470: ...468 FDEN C MEMO ...
Page 504: ...502 FDKN H MEMO ...
Page 580: ...578 FDR H MEMO ...
Page 698: ...696 V MULTI Models FDR258 A 308 A ...
Page 724: ...722 V MULTI MEMO ...
Page 1094: ...1092 FDC HKXR MEMO ...