SCM-C
244
2)
When not operating
The flap returns to the position of air flow
directly below, when operation has
stopped.
7.4.2 Details of operation control
(1)
Flap control
Control the flap by the AIRFLOW button on the wireless remote control
(a) AUTO (Natural flow)
The flap will be automatically set to the angle of air flow best to operation mode
1)
Starting time of operation
In case of cooling and
dry operation
Stops at the level
position for one
minute.
Sway operation
• The flap operation as shown above
will be repeated.
7.4
OUTLINE OF OPERATION CONTROL BY MICROCOMPUER
7.4.1 Table for operation control
Refering page
Functions
Content
High efficiency, low input rotary compressor
–
Wireless remote control
Dry
ON TIMER
OFF TIMER
Automatic fan control
M. C. (Micro computer
controlled) thermostat
Remote control flap
Comfort timer
Self Diagnosis
Function
Micro computer control
246
247
247
244
247
249
248
247
–
Low input rotary compressor with high efficiency is equipped.
All operation modes can be operated from distance place by the wireless remote
control. And also liquid crystal is used to show all kinds of operation or, off, air
flow switch, operation switch, timer switch, timer set, temperature set, flap control
Defumidifies while keeping room temperature to the thermostat setting level by
M. C. thermostat.
ON timer setting for anytime during 12 hours can be performed.
When OFF-TIMER operation is selected, the room temperature is automatically
controlled after a while, ensuring that the room is not too cold during cooling.
• During COOL and DRY: the pre-set temperature is raised by 0.5˚C at the start
of OFF-TIMER operation (when the timer is set). After that, the temperature
goes up by 0.5˚C every 30 minutes to become 1.5˚C higher within one hour.
Room unit air volume can be automatically controlled step by step, according to
the difference between room temperature and setting temperature.
1. Shorten pull down time for cooling operation.
2. Low noise level operation can performed by proper air volume.
M. C. thermostat improves on energy saving and comfort, by control-
ling room temperature with high accuracy.
The flap can be automatically controlled by operating wireless remote control.
• AUTO (Natural flow)
: Flap operation is automatically controlled.
• Swing
: This will swing the flap up and down.
• Memory flap
: Once the flap position is set, the unit memorizes
the position and continues to operate at the same
position from the next time.
The room temperature is checked 60 minutes before the timer is at ON. De-
pending on the temperature at that time, the operation starets 5 to 60 minutes
before the timer is at ON.
We are constantly trying to do better service to our customers by installing such
judges that show abnormality of each function as follows:
• Abnormality of heat exchanger thermistor:
RUN lamp flashing
• Abnormality of room temperature thermistor:
RUN lamp flashing
• Abnormality of indoor fan motor:
RUN lamp flashing.
Comf
or
tability
, Economical efficienc
y
, Operational simplicity
No lamp will flashing
when the unit is
operating
}
Summary of Contents for SRRM40HENG-L
Page 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Page 52: ...50 SRK GZ MEMO ...
Page 94: ...92 SRK H MEMO ...
Page 104: ...102 102 SRK C MEMO ...
Page 180: ...178 SCM HG 4room MEMO ...
Page 222: ...220 SCM HG 2room MEMO ...
Page 234: ...232 SCM CG 2room MEMO ...
Page 266: ...SCM C 264 MEMO ...
Page 406: ...404 FDT N C MEMO ...
Page 442: ...440 FDEN H MEMO ...
Page 470: ...468 FDEN C MEMO ...
Page 504: ...502 FDKN H MEMO ...
Page 580: ...578 FDR H MEMO ...
Page 698: ...696 V MULTI Models FDR258 A 308 A ...
Page 724: ...722 V MULTI MEMO ...
Page 1094: ...1092 FDC HKXR MEMO ...