
581
FDU-H
15.1 GENERAL INFORMATION
15.1.1 Specific features
(1)
Less refrigerant charge amount due to use of double phase refrigerant flow system. The total refrigerant charge amount has been
reduced by more than 50%.
(2)
The indoor outdoor interconnection signal wiring has been done away with. The microcomputer chip is installed in the indoor unit.
There is no need for the unit to communicate between the outdoor and indoor units so the unit is more resistant to electromagnetic
noise thus the incidence of microcomputer malfunction has been reduced. The compressor in the outdoor unit has its own self
protection function, that reacts according to abnormal high pressure and excessive high temperature.
(3)
There are only five power lines between the outdoor and indoor unit, As no signal wire is used there is no need to separate the
power line from the signal line. One cab tyre cable with 6 wires encased in one sheath is enough for conducting the wiring work
between the outdoor unit and the indoor unit. This contributes to simpler wiring work in the field.
(4)
All models have control valves protruding from the outdoor unit for faster flare connection work in the field.
(5)
Operation noise has been drastically reduced by increasing the number of high performance fans and by through sound insulation.
(6)
When installing, the optimum outside static pressure can be set using the fan controller.
(7)
With the height of all equipment made uniform at 360mm and neatly installed into the ceiling, the installation of equipment with
different capacities into the same ceiling space is made easy.
15.1.2 How to read the model name
Example: FDU
30 8 H EN-SA
Applicable power source ... See the specifications
Heat pump type
Series No.
Product capacity
Model name
FDU: High static pressure duct type wired remote
controller
FDC: Outdoor unit
Summary of Contents for SRRM40HENG-L
Page 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Page 52: ...50 SRK GZ MEMO ...
Page 94: ...92 SRK H MEMO ...
Page 104: ...102 102 SRK C MEMO ...
Page 180: ...178 SCM HG 4room MEMO ...
Page 222: ...220 SCM HG 2room MEMO ...
Page 234: ...232 SCM CG 2room MEMO ...
Page 266: ...SCM C 264 MEMO ...
Page 406: ...404 FDT N C MEMO ...
Page 442: ...440 FDEN H MEMO ...
Page 470: ...468 FDEN C MEMO ...
Page 504: ...502 FDKN H MEMO ...
Page 580: ...578 FDR H MEMO ...
Page 698: ...696 V MULTI Models FDR258 A 308 A ...
Page 724: ...722 V MULTI MEMO ...
Page 1094: ...1092 FDC HKXR MEMO ...