SCM-HG
(4 room)
142
3
When the decision frequency becomes 0 Hz when high pressure cut protection control is in operation.
Functional component
Description of operation
Calculated Hz
0 Hz
Calculated Hz
0 Hz
Calculated Hz
0 Hz
Decision frequency
16 Hz
0 Hz
Decision frequency
According to 16 Hz
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
All Opened
According to Hz
75 pulses
All closed
All opened
According to Hz
According to 16 Hz
All closed
All opened
According to Hz
According to 16 Hz
All closed
All opened
75 pulses
All closed
0 Hz command
1
0 Hz command
2
0 Hz command
3
2 minutes
2 minutes
2 minutes
2 minutes
2 minutes
55 seconds
55 seconds
55 seconds
55 seconds
2 minutes
2 minutes
Indoor unit command frequency
Outdoor unit frequency
Outdoor unit fan
4-way valve
Solenoid valve
(SVDf)
Solenoid valve
(SVA, B, C, D)
[Operating
→
Stopped units
1
]
Solenoid valve
(SVA, B, C, D)
[Operating
→
Stopped units
2
]
Solenoid valve
(SVA, B, C, D)
[Operating
→
Stopped units
3
]
Solenoid valve
(SVA, B, C, D)
[Stopped units]
Expansion valve
(EVA, B, C, D)
[Operating
→
Stopped units
1
]
Expansion valve
(EVA, B, C, D)
[Operating
→
Stopped units
3
]
Expansion valve
(EVA, B, C, D)
[Operating
→
Stopped units
2
]
Expansion valve
(EVA, B, C, D)
[Stopped units]
2 minutes 25 seconds
2 minutes 25 seconds
2 minutes 55 seconds
3) This is only for 1 or 2 units when 3 are in operation. In addition, the high pressure cut protection control operates when
the serial signal from the indoor unit has stopped (interruption of power supply or signal wire).
4) If a protection function is activated during the operation of the high pressure cut protection control, the protection
function has priority.
Summary of Contents for SRRM40HENG-L
Page 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Page 52: ...50 SRK GZ MEMO ...
Page 94: ...92 SRK H MEMO ...
Page 104: ...102 102 SRK C MEMO ...
Page 180: ...178 SCM HG 4room MEMO ...
Page 222: ...220 SCM HG 2room MEMO ...
Page 234: ...232 SCM CG 2room MEMO ...
Page 266: ...SCM C 264 MEMO ...
Page 406: ...404 FDT N C MEMO ...
Page 442: ...440 FDEN H MEMO ...
Page 470: ...468 FDEN C MEMO ...
Page 504: ...502 FDKN H MEMO ...
Page 580: ...578 FDR H MEMO ...
Page 698: ...696 V MULTI Models FDR258 A 308 A ...
Page 724: ...722 V MULTI MEMO ...
Page 1094: ...1092 FDC HKXR MEMO ...