365
FDT(N)-C
9.1.2
How to read the model name
Exampie: FDTN
P 30 8
C EN - S
9.1
GENERAL INFORMATION
9.1.1
Specific features
(1)
Less refrigerant charge amount due to use of double phase refrigerant flow system. The total refrigerant charge amount has
been reduced by more than 50%.
(2)
The indoor outdoor interconnection signal wiring has been done away with. The microcomputer chip is installed in the
indoor unit. There is no need for the unit to communicate between the outdoor and indoor units so the unit is more resistant
to electromagnetic noise thus the incidence of microcomputer malfunction has been reduced. The compressor in the outdoor
unit has its own self protection function, that reacts according to abnormal high pressure and excessive high temperature.
(3)
There are only four power lines between the outdoor and indoor unit. As no signal wire is used there is no need to separate the
power line from the signal line. One cab tyre cable with 4 wires encased in one sheath is enough for conducting the wiring
work between the outdoor unit and the indoor unit. This contributes to simpler wiring work in the field.
(4)
All air supply ports have auto swing louvers. The indoor fan motor has two speeds of high and low.
(5)
All models have service valves protruding from the outdoor unit for faster flare connection work in the field.
(6)
Low sound level
Operating noise has been remarkably reduced due to adoption of the crescent turbo fan which cuts off wind-blowing noise
and also console type of cabinet which is highly effective to protect vibration.
(7)
700mm high drain head
Adoption of drain pump with high drain head and high capacity (600cc/min) has made it possible to have maximum 700
mm(form below ceiling drain head.[In case 700mm drain head is required, set it up close to the unit. It is impossible to do
piping on down slope.]
Applicable power source ... See the specifications
Cooling only type
Series No.
Nominal capacity
P:R407C model
P
:R22 model
Model name
FDTN : Ceiling recessed type unit with
wireless remote controller
FDT : Ceiling recessed type unit with
wired remote controller
FDC : Outdoor unit
(blank)
Summary of Contents for SRRM40HENG-L
Page 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Page 52: ...50 SRK GZ MEMO ...
Page 94: ...92 SRK H MEMO ...
Page 104: ...102 102 SRK C MEMO ...
Page 180: ...178 SCM HG 4room MEMO ...
Page 222: ...220 SCM HG 2room MEMO ...
Page 234: ...232 SCM CG 2room MEMO ...
Page 266: ...SCM C 264 MEMO ...
Page 406: ...404 FDT N C MEMO ...
Page 442: ...440 FDEN H MEMO ...
Page 470: ...468 FDEN C MEMO ...
Page 504: ...502 FDKN H MEMO ...
Page 580: ...578 FDR H MEMO ...
Page 698: ...696 V MULTI Models FDR258 A 308 A ...
Page 724: ...722 V MULTI MEMO ...
Page 1094: ...1092 FDC HKXR MEMO ...