FDC-HKX
752
(3)
Operation chart
Since the Multi KX series air conditioner units are free multitype to which the indoor units of different capacity and different
model can be combined, the operation characteristics of all combinations are very complicated, therefore only the individual
operation characteristics of indoor and outdoor units are shown. For the combined operation characteristics, calculate them with
the method shown in the next page.
(a)
Operating characteristic of outdoor unit
Cooling input
Heating input
Cooling running current
Heating running current
Inrush current (MAX.)
Cooling power factor
Heating power factor
(380 V/415 V)
Item
Models
FDCJ140HKXE2B
6.8/6.8
5.7/5.9
10.7/10.2
8.8/8.4
5
97/93
98/98
9.8/9.8
8.3/8.4
15.7/14.6
13.0/12.0
48
95/93
97/97
11.7/11.7
9.7/9.8
19.3/19.0
15.7/15.7
70
92/86
94/95
FDCJ224HKXE2B
FDCJ280HKXE2B
kW
A
A
%
Cooling input
Heating input
Cooling running current
Heating running current
Inrush current (MAX.)
Cooling power factor
Heating power factor
(380 V/415 V)
Item
Models
FDCP140HKXE2B
6.8/6.8
6.0/6.1
10.7/10.2
9.3/8.6
5
97/93
98/99
9.8/9.8
9.3/9.4
15.7/14.6
14.7/14.0
48
95/93
96/93
11.7/11.7
11.2/11.4
19.3/19.0
17.6/16.8
70
92/86
97/94
FDCP224HKXE2B
FDCP280HKXE2B
kW
A
A
%
Note (1) This packaged air-conditioner is manufactured and tested in conformity with the following standard.
JIS B8616 “UNITARY AIR-CONDITIONERS”
(b)
Operating characteristic of indoor unit
Item
Models
FDT Series
FDT Series
(220 V/240 V)
Power input (kW)
Running current (A)
0.09/0.10
0.40/0.44
0.10/0.12
0.45/0.49
0.10/0.12
0.47/0.50
0.11/0.13
0.50/0.55
0.17/0.20
0.75/0.81
0.21/0.24
0.93/1.02
28
36
45
56
71
90
112
140
Item
Models
FDTW Series
FDTW Series
(220 V/240 V)
Power input (kW)
Running current (A)
0.43/0.43
0.09/0.10
0.43/0.44
0.10/0.11
0.48/0.50
0.12/0.13
0.57/0.59
0.18/0.20
0.86/0.89
0.20/0.24
0.90/0.98
28
45
56
71
90
112
140
Notes (1) This packaged air-conditioner is manufactured and tested in conformity with the following standard.
JIS B8616 “UNITARY AIR-CONDITIONERS”
(2) The values shown in the above table are common to both cooling and heating operations.
Summary of Contents for SRRM40HENG-L
Page 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Page 52: ...50 SRK GZ MEMO ...
Page 94: ...92 SRK H MEMO ...
Page 104: ...102 102 SRK C MEMO ...
Page 180: ...178 SCM HG 4room MEMO ...
Page 222: ...220 SCM HG 2room MEMO ...
Page 234: ...232 SCM CG 2room MEMO ...
Page 266: ...SCM C 264 MEMO ...
Page 406: ...404 FDT N C MEMO ...
Page 442: ...440 FDEN H MEMO ...
Page 470: ...468 FDEN C MEMO ...
Page 504: ...502 FDKN H MEMO ...
Page 580: ...578 FDR H MEMO ...
Page 698: ...696 V MULTI Models FDR258 A 308 A ...
Page 724: ...722 V MULTI MEMO ...
Page 1094: ...1092 FDC HKXR MEMO ...