401
FDT(N)-C
Model FDTNP308CES-S
TB
RD/WH
BK/WH
BK/RD
Y/GN
BK
DR
DR
Tho-R
63H
1
CnL
LED-R
LED-G
(Check)
(Run)
CnE
Vao
(Checker)
CnA1
Tro
CnA2
BK
Tho-D
BK
Tho-A
6
14V
BK/RD
BL
BL
P
P
BR
BR
26
21
20
19
18
13
12
2
1
13
24
5
6
Printed circuit board
3
HL
UH
A1
CF
0
A2
28
X
02
X
01
X
03
X
04
X
06
X
01
220/240V
7
PC
CnR
CnM
1
CH
X
04
X
02
X
03
X
06
1
2/N
3
F(3.15A)
OR/WH
OR/WH
OR
OR
WH
BR
BL
BK
BL
RD
Y/GN
WH
WH
BL
RD
WH
BL
BK/WH
RD
CT2
CT1
V
UW
52C
RD/WH
RD
BK/WH
WH
L
3
L
1
N
L
2
TB
SV
52C
FM
O
(49F
O1
)
CM
NR
LM
FM
I
(49F
I
)
DM
Y / G
N
RD
WH
BK
TB
1
2
9
X
1
X
3
X
4
X
7
X
5
X
2
WH
WH
WH
OR
OR
RD
RD
BL
BK
BL
BK
WH
WH
Y/GN
CnJ
CnF
1
CF
I
38
7
6
5
L
H
UH
OR
WH
WH
RD
WH
RD
BR
BR
GR
CnF
1
CnJ
CnR
CnI
CnI
CnR
41
3
X
1
X
2
X
3
X
4
X
7
X
5
Va
I
CnH
CnN
CnL
CnV
CnB
2
CnB
CnA
CnN
CnH
2
Th
I
–A
Th
I
–R
BK
BK
BK
BK
RD
RD
BK
BK
BK
RD
BK
BR
CnW
1
CnW
2
CnQ
Tr
I
T
est
XR1
XR2
XR3
XR4
XR5
Option
Receiver amp
Wireless
remote
controller
LED1
LED2
SW
( 3 )
( 3 )
( 3 )
SW2
SW3
ON
ON
OFF
OFF
1 2 3 4
1 2 3 4
PC
FS
12V
220/240V
Printed circuit board
1
2
3
Indoor Unit
Outdoor Unit
CnT
Power Source
3 Phase 380/415V 50Hz
Meaning of marks
Mark
Parts name
Mark
Parts name
CF
I
Capacitor for FM
I
SW
Back up switch (ON/OFF)
CF
O
Capacitor for FM
O
SW2, 3
Changeover switch
CH
Crankcase heater
TB
T
erminal block (
mark)
CM
Compressor motor
Th
I
-A
Thermistor
CnA ~ W
Connector
Th
l
-R
Thermistor
DM
Drain motor
Tho-A
Thermistor
F
Fuse
Tho-D
Thermistor
FM
I
Fan motor (Indoor unit)
Tho-R
Thermistor
FM
O
Fan motor (Outdoor unit)
T
rI,
T
ro
T
ransformer
FS
Float switch
V
al,
V
a
o
V
aristor
LED1
Indication lamp (Green - Run)
63H
1
High pressure switch (for protection)
LED2
Indication lamp
(Y
ellow -
Ti
mer/Check)
49Fo
Internal thermostat for FMo
LED-G
Indication lamp (Green)
49F
I
Internal thermostat for FM
I
LED-R
Indication lamp (Red)
CT1,2
Current sensor
LM
Louver motor
52C
Magnetic contactor for CM
LS
Limit switch
X1~7, X01~06
Auxiliary relay
NR
Sur
ge suppressor
v
T
erminal (F)
PC
Photo coupler
■
Connector
SV
Solenoid coil (for control)
Color mark
Mark
Color
BK
Black
BL
Blue
BR
Brown
GR
Gray
OR
Orange
P
Pink
RD
Red
WH
White
Y
Y
ellow
Mark
Color
BK/RD
Black/Red
BK/WH
Black/White
OR/WH
Orange/White
RD/WH
Red/White
Y/GN
Y
ellow/Green
Summary of Contents for SRRM40HENG-L
Page 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Page 52: ...50 SRK GZ MEMO ...
Page 94: ...92 SRK H MEMO ...
Page 104: ...102 102 SRK C MEMO ...
Page 180: ...178 SCM HG 4room MEMO ...
Page 222: ...220 SCM HG 2room MEMO ...
Page 234: ...232 SCM CG 2room MEMO ...
Page 266: ...SCM C 264 MEMO ...
Page 406: ...404 FDT N C MEMO ...
Page 442: ...440 FDEN H MEMO ...
Page 470: ...468 FDEN C MEMO ...
Page 504: ...502 FDKN H MEMO ...
Page 580: ...578 FDR H MEMO ...
Page 698: ...696 V MULTI Models FDR258 A 308 A ...
Page 724: ...722 V MULTI MEMO ...
Page 1094: ...1092 FDC HKXR MEMO ...