Procedure 5-39: Clear
″
manual switch
″
condition
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear a
manual switch
condition indicated
by a lighted Abnormal (
MN/ABN
) LED on the SYSCTL faceplate, and
reported as a Standing Condition (SC) in the WaveStar
®
CIT Alarm
List.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear a
manual switch
condition.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click on the
Alarm List
button and locate the
manual switch
condition in the resulting alarm
list and note the corresponding AID and the Alarm Entity Type
(OCN).
............................................................................................................................................................
2
From the System View menu, select
Fault
→
Protection Switch
,
highlight the appropriate 1+1 Line Protection group or Path Protection
group, and then click
Select
.
Result:
On the right side of the Switch Protection window,
the Switch Type: pull-down menu appears.
............................................................................................................................................................
3
From the Switch Type: pull-down menu, select
Reset
and click
Apply
.
Result:
A warning message appears asking you to confirm
executing this command.
............................................................................................................................................................
4
Click
Yes
to release the manual switch. Click
Close
to exit the
Switch Protection window.
............................................................................................................................................................
5
From the System View, click the
Alarm List
button and click
Refresh
.
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 1 1 7