Result:
A warning message appears asking you to confirm
executing this command. Click
Yes
. Proceed to
............................................................................................................................................................
8
If the port is connected to test equipment, you have the following
options to clear the alarm.
1.
Change the test set DS3 set-up to match the Signal Format
parameter for that port: either Framed (M13), C-bit, or Clear
Channel, or
2.
Disconnect the test set, or
3.
Ignore the alarm until the test set is disconnected, (recommended
method), or
4.
Change the provisioning of the port that is connected to the test
equipment (continue with
). This method is not
recommended. The port must be reprovisioned after the test set is
disconnected.
............................................................................................................................................................
9
In the Transmission section of the Configure Equipment window,
change the Signal Format parameter for that port to match the test set
DS3 set-up: either Framed (M13), C-Bit, or Clear Channel and click
Apply
.
Result:
A warning message appears asking you to confirm
executing this command. Click
Yes
. Proceed to
............................................................................................................................................................
10
In the Transmission section of the Configure Equipment window,
change the Signal Format parameter for that port to Clear Channel or
another appropriate signal type and click
Apply
.
Result:
A warning message appears asking you to confirm
executing this command. Click
Yes
. Continue with
............................................................................................................................................................
11
Click
Close
on the Configure Equipment window.
............................................................................................................................................................
12
From the System View, click the
Alarm List
button and click
Refresh
.
Procedure 5-24: Clear
″
inc. DS3 Cbit
Mismatch
″
alarm
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 7 3