5
Log in to the far-end network element.
Reference:
“Procedure 6-2: Connect personal computer
............................................................................................................................................................
6
From the System View menu, select the
View
→
Cross-Connection
.
............................................................................................................................................................
7
Are there incomplete or incorrect cross-connections?
If...
Then...
Yes
Continue with
No
Proceed to
............................................................................................................................................................
8
From the System View menu, select
Configuration
→
Cross-Connection
to start the Cross-Connection Wizard. Use the
Cross-Connection Wizard to correct the provisioning.
............................................................................................................................................................
9
From the System View, click the
Alarm List
button and click
Refresh
.
............................................................................................................................................................
10
Is the
inc. VT
alarm still present?
If...
Then...
Yes
Continue with
No
Proceed to
............................................................................................................................................................
11
One at a time, log in to every shelf where the service should be
pass-through cross-connected (for example, main-1-1-1-1 to
main-1-1-1-1). Select the
View
→
Cross-Connection
command from
the System View menu at each shelf to determine if the time slot
identified in
is cross-connected as specified in circuit layout or
other office records.
Procedure 5-35: Clear
″
inc. VT
″
conditions/alarms
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 1 0 9