dormant/exec code mismatch
....................................................................................................................................................................................................................................
dormant/exec code
mismatch
The software generic in the dormant area does not match the generic
currently running on the NE.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Not Alarmed
AID (type)
Blank
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
EOC
Effect on
Service
Standing Condition (SC)
Alarm Entity
Type
COM
Description
dormant/exec code mismatch
Likely Cause
User downloaded, but did not apply, a software
generic to the dormant area that is different than
the software generic currently running on the NE.
Visible
indication
None.
Action
Proceed to
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
3 - 1 9