4
Visually check the local receive fiber connections between the circuit
pack faceplate and the LGX panel or equivalent connection point for
faulty connections or damage.
If faulty connections or
damage...
Then...
was found,
Follow local procedures to
repair/replace as necessary. Then
continue with
was not found,
Proceed to
............................................................................................................................................................
5
From the System View, click the
Alarm List
button and click
Refresh
.
............................................................................................................................................................
6
Is the
inc. OCN
condition/alarm still present?
If...
Then...
Yes
Continue with
No
STOP! End of Procedure.
............................................................................................................................................................
7
CAUTION
Service disruption hazard
Disconnecting cables and/or replacing circuit packs may disrupt
service.
Before taking action, determine the extent of service disruption
caused by disconnecting cables or replacing a circuit pack. Then,
perform the action(s) deemed appropriate in light of the traffic
being carried and the nature of the failure.
Replace the affected local combination circuit pack.
Procedure 5-29: Clear
″
inc. OCN
″
conditions/alarms
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 8 9