Procedure 5-26: Clear
″
inc. (from fiber) DS3
″
conditions
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear the following
inc. (from fiber)
DS3
conditions reported as Standing Conditions (SC) in the
WaveStar
®
CIT Alarm List:
•
inc. (from fiber) DS3 AIS
•
inc. (from fiber) DS3 LOF
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear an
inc. (from fiber) DS3
condition.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click the
Alarm List
button
and locate the
inc. (from fiber) DS3
condition in the resulting
alarm list.
............................................................................................................................................................
2
Refer to the Probable Cause column in the alarm list, determine the
port affected, and note the corresponding AID.
............................................................................................................................................................
3
Using circuit layouts and/or office records, identify the other network
element where the alarmed DS3 is terminated.
............................................................................................................................................................
4
Important! A likely cause of an
inc. (from fiber) DS3
condition at the local network element is a problem/failure at the
other network element where the alarmed DS3 is terminated.
Consult and follow local procedures for addressing any DS3-related
alarms/conditions at the other network element where the alarmed
DS3 is terminated.
............................................................................................................................................................
5
At the local network element, click the
Alarm List
button and click
Refresh
.
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 7 9