Alarm list with alarm levels
....................................................................................................................................................................................................................................
Overview
This section provides the alarm list, including the alarm level(s).
Alarm list
Important! The alarm level for certain alarms is provisionable.
In the table below, a bold
X
identifies the default alarm level for
alarm messages that have provisionable levels. If there are
multiple levels listed, yet there is no bold
X
, the alarm level for
that alarm or condition is determined by the provisioning of the
equipment. For example, for CP removed: the removal of an
unprotected, active CP is always Critical (SA) and the removal of
a protected CP is always Minor (NSA).
Table 2-1
Metropolis
®
DMX
plore, Release 2.1 alarm list
Alarm/Condition Name
Alarm/Condition
Type
Alarm/Condition Level
Go to
CR
MJ
MN
SC
1
-48V power/fuse FA failed
PWR
X
X
X
-48V power/fuse FB failed
PWR
X
X
X
ABN condition
MAN
X
2
Locate the
corresponding Not
Alarmed (SC) in the
alarm list and
proceed to the
appropriate
procedure to
release/clear the
condition.
ACO active
INHAUDB
X
No action necessary.
AGNE communication failure
PRCDRERR
X
copy program IP
EOC
X
No action necessary.
CP failed
FACTERM
X
X
“Procedure 6-4:
Replace Combination
circuit pack” (6-148)