CP failed
....................................................................................................................................................................................................................................
CP failed
Internal equipment failure of the specified circuit pack or
communications problem between the specified circuit pack and the
System Controller (SYSCTL) circuit pack was detected.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Critical (CR), Minor (MN)
AID (type)
Slot
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
FACTERM
Effect on
Service
CR = SA
MN = NSA
Alarm Entity
Type
EQPT
Description
CP failed
Likely Cause
An unprotected circuit pack carrying service
failed: CR (SA).
A protected circuit pack failed or an unprotected
circuit pack NOT carrying service failed: MN
(NSA).
Visible
indication
Lighted
CR/MJ
or
MN/ABN
LED on SYSCTL
faceplate and a continuously lighted
FAULT
LED
on the failed circuit pack.
Action
Proceed to
“Procedure 6-4: Replace Combination
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................