inc. (from DSX) DS3 sig. failed
....................................................................................................................................................................................................................................
inc. (from DSX) DS3 sig.
failed
The bit error ratio (BER) in the DS3 signal incoming from the DSX-3
exceeds the provisioned failure threshold, 10
-6
(default).
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Critical (CR), Major (MJ), Minor (MN), Not
Alarmed
CR is the default level.
AID (type)
DS3 Port
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
T-BERL
Effect on
Service
CR, MJ, MN = SA or NSA
Not Alarmed = Standing Condition (SC)
Alarm Entity
Type
T3
Description
inc. (from DSX) DS3 sig. failed
Likely Cause
Failure of the interfacing customer equipment or
facility (towards the DSX-3); cross-talk in office
wiring; failure of the circuit pack.
Visible
indication
Lighted
CR
/
MJ
or
MN/ABN
LED on SYSCTL
faceplate and a flashing
FAULT
LED on the
alarmed circuit pack.
Action
Proceed to
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
3 - 4 5