the software (
cpy-mem
), takes approximately 12 minutes. The
second part, the reset of the shelf and the automatic
apply/activation of the downloaded software (
apply
), takes
approximately 10 minutes.
While the transfer is in progress, the following Progress
Indicator appears.
............................................................................................................................................................
6
After the FTTD download is complete, a completion message appears.
Click
OK
.
Result:
The second part of the initial software download
begins, the reset of the shelf and the apply/activation of the
downloaded software (
apply
).
During the automatic reset and the apply, the SYSCTL circuit
pack cycles through a series of changes in the LEDs’ state:
•
MN/ABN
LED extinguishes
•
MN/ABN
LED and
ACO/TST
LED simultaneously light for
approximately 12 seconds and then extinguish
•
MN/ABN
LED and
ACO/TST
LED simultaneously light for
approximately 8 seconds and then extinguish
•
CR/MJ
LED flashes eleven times
•
All LEDs remain extinguished; the reset is complete.
............................................................................................................................................................
7
Establish a WaveStar
®
CIT session (specifying either OSI or Serial in
the
Connection Type:
field) and re-log in to your Metropolis
®
DMXplore shelf.
Procedure 6-3.4: Initial software generic
installation via FTTD (2.0 boot code)
Supporting procedures
....................................................................................................................................................................................................................................
6 - 8 8
Lucent Technologies
365-372-333 R2.1