CP removed or CP failure
....................................................................................................................................................................................................................................
CP removed
A circuit pack was removed from the shelf or the circuit pack has a
failed power module.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Critical (CR), Minor (MN)
AID (type)
Slot
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
FACTERM
Effect on
Service
CR = SA
MN = NSA
Alarm Entity
Type
EQPT
Description
CP removed or CP failure
Likely Cause
An unprotected circuit pack carrying service was
removed from the shelf or the circuit pack power
module failed: CR (SA).
A protected circuit pack or an unprotected circuit
pack NOT carrying service was removed from the
shelf or the circuit pack power module failed: MN
(NSA).
Visible
indication
Lighted
CR/MJ
or
MN/ABN
LED on SYSCTL
faceplate.
Action
Proceed to
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
3 - 1 4
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005