Reference:
“Procedure 6-4: Replace Combination circuit
............................................................................................................................................................
8
From the System View, click the
Alarm List
button and click
Refresh
.
............................................................................................................................................................
9
Is the
inc. OCN
condition/alarm still present?
If...
Then...
Yes
Remove the replacement combination
circuit pack and return the original
circuit pack to the slot, then continue
with
No
STOP! End of Procedure.
............................................................................................................................................................
10
Important! At this point, the local network element is operating
correctly. The trouble is in the far-end network element or in the
fiber/cable between the far-end network element and the local
network element.
Consult and follow local procedures for addressing OCN-related
conditions/alarms at the far-end network element.
............................................................................................................................................................
11
From the System View at the local network element, click the
Alarm
List
button and click
Refresh
.
............................................................................................................................................................
12
Is the
inc. OCN
condition/alarm still present?
If...
Then...
Yes
Continue with
No
STOP! End of Procedure.
Procedure 5-29: Clear
″
inc. OCN
″
conditions/alarms
Trouble clearing procedures
....................................................................................................................................................................................................................................
5 - 9 0
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005