5
Do office records show that the required socket should contain a
pluggable transmission module?
If...
Then...
Yes,
Obtain the missing pluggable
transmission module and install
it into the required slot.
Refer to the pluggable
transmission module installation
procedure in the Metropolis
®
DMXplore Access Multiplexer
User Operations Guide,
365-372-332.
No,
Perform the following:
1. Use
View
→
Cross-Connections
to obtain
a current list of
cross-connections. If
required, use
Configuration
→
Cross-Connections
to
access the Cross-Connection
Wizard and delete any
cross-connections to the
affected pluggable
transmission module.
2. Select
Configuration
→
Update System
→
Update All
.
A dialog box appears asking
you to confirm executing this
command. Click
Yes
.
This system update clears the
Pluggable Transmission
Module removed
alarm.
............................................................................................................................................................
6
From the WaveStar
®
CIT System View, click the
Alarm List
button
and click
Refresh
.
Procedure 5-46: Clear
″
Pluggable
Transmission Module removed
″
alarm
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 1 3 3