AGNE communication failure
....................................................................................................................................................................................................................................
AGNE communication
failure
Metropolis
®
DMXplore cannot establish communication with the
designated alarm gateway network element (AGNE), or the AGNE
cannot establish communication with a network element in the same
alarm group or the AGNE has lost communication with a network
element in the same alarm group.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Major (MJ)
AID (type)
Blank
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
PRCDRERR
Effect on
Service
NSA
Alarm Entity
Type
COM
Description
AGNE communication failure
Likely Cause
AGNE has not been provisioned or has failed.
Visible
indication
Lighted
CR/MJ
LED on SYSCTL faceplate.
Action
Proceed to
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
3 - 9