10
If the login is successful, the NE Legal Notice appears.
If the login is not successful, try one of the following:
•
If you are connected locally to the
RS232
serial port, check cable
connections. Check COM port baud rate settings by selecting
Administration
→
Serial COM Selection
from the WaveStar
®
CIT Network View. Try different COM port settings. The NE
default baud rate setting for the
RS232
serial port (cit-1) is 9600.
The rate of the COM port must match the rate of the CIT port on
the NE.
•
If you are connected locally to the
LAN
port and using the OSI
protocol, check your network card (NIC) settings. Some NIC
cards have an 802.1b option which must be enabled for OSI to
work.
•
If you are connected locally to the
LAN
port and using the
TCP/IP protocol, make sure you are entering the correct TCP/IP
address.
Important! Your NE software Release number and User
Privilege Level may be different. Your notice should be similar to
Figure 6-6, “NE level legal notice” (6-32)
Figure 6-6 NE level legal notice
Procedure 6-2: Connect personal computer
(PC) and establish WaveStar
®
CIT session
Supporting procedures
....................................................................................................................................................................................................................................
6 - 3 2
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005