Procedure 5-42: Clear
″
neighbor SYSCTL CP unavailable (nbr
tid = TID)
″
alarm
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear a
neighbor SYSCTL CP unavailable
alarm indicated by a lighted Major (
CR/MJ
) LED on local the
SYSCTL faceplate, and reported as Major in the WaveStar
®
CIT
Alarm List.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
and
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear a
neighbor SYSCTL CP
unavailable (nbr tid = TID)
alarm.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click the
Alarm List
button
and locate the
neighbor SYSCTL CP unavailable (nbr tid = TID)
alarm and the
section DCC failed
alarm in the resulting alarm list.
............................................................................................................................................................
2
Refer to the Probable Cause column in the alarm list, determine the
circuit pack affected, and note the corresponding AID.
............................................................................................................................................................
3
Refer to the Description column in the alarm list, and note the nbr tid
= TID (neighbor target identifier = LT-DMXPLORE [default]).
Important! If the nbr tid = UNKNOWN, consult your network
diagrams and/or local procedures and determine the TID of the
remote node that is connected to the affected OCN port.
............................................................................................................................................................
4
Log in to the neighboring NE (using its TID) via TCP/IP or OSI or
dispatch local craft to the remote site and login to NE.
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 1 2 5