Procedure 5-47: Clear
″
Port administratively disabled
″
condition
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear a
Port administratively disabled
condition indicated by a lighted Abnormal (
MN/ABN
) LED on the
SYSCTL faceplate, and reported as a Standing Condition (SC) in the
WaveStar
®
CIT Alarm List. The condition indicates that a user has
disabled the Port Administration Control parameter.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear a
Port administratively
disabled
condition.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click the Alarm List button
and locate the
Port administratively disabled
condition in the
resulting alarm list.
............................................................................................................................................................
2
Refer to the Probable Cause column in your alarm list, determine the
circuit pack and port affected, and note the corresponding AID.
............................................................................................................................................................
3
From the System View menu, select
Configuration
→
Equipment
,
expand the appropriate circuit pack, select the required port, and click
Select
.
Result:
The port provisionable parameters appear.
............................................................................................................................................................
4
Provision the Port Administration Control parameter as
Enabled
and
click
Apply
.
Result:
A warning message appears asking you to confirm
executing this command. Click
Yes
and
Close
.
............................................................................................................................................................
5
From the System View, click the
Alarm List
button and click
Refresh
.
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 1 3 5