5
From the System View menu, select
Reports
→
Equipment Lists
→
Pack
. Click on Shelf and
Select
to obtain the Circuit Pack List.
Observe the circuit pack information for the required slot.
............................................................................................................................................................
6
Compare the correct circuit pack information from office records with
the circuit pack information from the Circuit Pack List and the circuit
pack that is physically in the required slot.
............................................................................................................................................................
7
Is the correct circuit pack physically installed in the required slot?
If ...
Then...
Yes,
Select
Configuration
→
Update
System
→
Update Inventory
.
A dialog box appears asking you
to confirm executing this
command. Click
Yes
.
No,
Perform the following:
1. Obtain the correct type of
circuit pack (according to
office records and the Circuit
Pack List) for the required
slot.
2. Replace the wrong circuit
pack currently in the required
slot with the correct circuit
pack. Refer to the
appropriate circuit pack
replacement procedure in
Chapter 6, “Supporting
procedures”
............................................................................................................................................................
8
From the WaveStar
®
CIT System View, click
Alarm List
button and
click
Refresh
.
Procedure 5-5: Clear
″
CP not allowed -
eqpt
″
alarm
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 2 1