Procedure 5-33: Clear
″
inc. VCG LFD
″
condition
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear an
inc. VCG LFD
condition indicated
by a lighted abnormal (
MN/ABN
) LED on the SYSCTL faceplate, and
reported as a Standing Condition (SC) in the WaveStar
®
CIT Alarm
List.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear an
inc. VCG LFD
condition.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click the
Alarm List
button
and locate the
inc. VCG LFD
condition in the resulting alarm list.
............................................................................................................................................................
2
Refer to the Probable Cause column in the alarm list, determine the
circuit pack affected by the
inc. VCG LFD
condition, and note the
corresponding VCG AID.
............................................................................................................................................................
3
Important! The Ethernet circuit packs at both terminating
network elements must support standard Generic Framing
Procedure (GFP) encapsulation (ITU G.7041) for Ethernet over
SONET mapping.
Using office records, verify that the Ethernet circuit packs at both
terminating network elements support standard Generic Framing
Procedure (GFP) encapsulation (ITU G.7041).
If required, replace the near-end or far-end Ethernet circuit pack.
Reference:
“Procedure 6-5: Replace Ethernet circuit pack”
............................................................................................................................................................
4
From the System View, click the
Alarm List
button and click
Refresh
.
Trouble clearing procedures
....................................................................................................................................................................................................................................
5 - 1 0 4
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005