Procedure 5-5: Clear
″
CP not allowed - eqpt
″
alarm
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear a
CP not allowed - eqpt
alarm
indicated by a lighted Major (
CR/MJ
) or Minor (
MN/ABN
) LED on the
SYSCTL faceplate, and reported as major or minor in the WaveStar
®
CIT Alarm List.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
and
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear a
CP not allowed - eqpt
alarm.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click on the
Alarm List
button and locate the
CP not allowed - eqpt
alarm in the resulting
alarm list.
............................................................................................................................................................
2
Determine the alarm level(s) for the active
CP not allowed - eqpt
alarm(s) (for example, MJ or MN). Clear the alarms in order of
severity, MJ (SA) and then MN (NSA).
Important! The
CP not allowed - eqpt
alarm is either MJ
(SA) when the circuit pack is active (either working and
unprotected or the protection switch failed) or MN (NSA) when
the circuit pack is protected and protection switch operated
normally.
............................................................................................................................................................
3
Refer to the Probable Cause column in the alarm list (example in
), determine the circuit pack affected, and note the corresponding slot
AID.
............................................................................................................................................................
4
Using office records, determine the correct circuit pack type for the
required slot.